EMC2103 数据表(PDF) 21 Page - SMSC Corporation

部件名 EMC2103
功能描述  RPM-Based Fan Controller with HW Thermal Shutdown
PDF  84 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  SMSC [SMSC Corporation]
网页  http://www.smsc.com
标志 SMSC - SMSC Corporation

EMC2103 数据表(HTML) 21 Page - SMSC Corporation

Back Button EMC2103 Datasheet HTML 17Page - SMSC Corporation EMC2103 Datasheet HTML 18Page - SMSC Corporation EMC2103 Datasheet HTML 19Page - SMSC Corporation EMC2103 Datasheet HTML 20Page - SMSC Corporation EMC2103 Datasheet HTML 21Page - SMSC Corporation EMC2103 Datasheet HTML 22Page - SMSC Corporation EMC2103 Datasheet HTML 23Page - SMSC Corporation EMC2103 Datasheet HTML 24Page - SMSC Corporation EMC2103 Datasheet HTML 25Page - SMSC Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 21 / 84 page
background image
RPM-Based Fan Controller with HW Thermal Shutdown
Datasheet
SMSC EMC2103
21
Revision 0.85 (01-29-08)
DATASHEET
5.1
Critical/Thermal Shutdown
The EMC2103 provides a hardware Critical/Thermal Shutdown function for systems. Figure 5.2 is a
block diagram of this Critical/Thermal Shutdown function. The Critical/Thermal Shutdown function
accepts configuration information from the fixed states of the SHDN_SEL pin as described in
Section 5.1.1.
Each of the software programmed temperature limits can be optionally configured to act as inputs to
the Critical / Thermal Shutdown independent of the hardware shutdown operation. When configured to
operate this way, the SYS_SHDN# pin will be asserted when the temperature meets or exceeds the
limit. The pin will be released when the temperature drops below the limit however the individual status
bits will not be cleared if set (see Section 6.13).
The analog portion of the Critical/Thermal Shutdown function monitors the hardware determined
shutdown channel (see Section 5.1.1). This measured temperature is then compared with TRIP_SET
point. This TRIP_SET point is set by the system designer with a single external resistor divider as
described in Section 5.1.2.
The SYS_SHDN is asserted when the indicated temperature meets or exceeds the temperature
threshold (TP) established by the TRIP_SET input pin for a number of consecutive measurements
defined by the fault queue. If the HW_SHDN output is asserted and the temperature drops below the
threshold, then it will be set to a logic ‘0’ state.
Figure 5.2 Block Diagram of Critical / Thermal Shutdown
Temperature
Conversion
HW_SHDN
H/W Thermal
Shutdown Sensor
Critical / Thermal Shutdown
SMBus
Traffic
SW_SHDN
SYS_SHDN
Temperature
Conversion
Software
Shutdown Enable
TRIP_SET
Resistor
Decode
VDD
SHDN_SEL



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com