| 数据搜索系统,热门电子元器件搜索 |
|
L9733XPTR 数据表(PDF) 28 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9733XPTR 数据表(HTML) 28 Page - STMicroelectronics |
|
28 / 35 page ![]() Fault operation L9733 28/35 DocID11319 Rev 12 – On the rising edge (low to high transition) at the corresponding parallel input pin (only for Outputs 6-8). – If the switching OFF protection is not active the On phase overcurrent protection is a linear current limitation and no diagnosis is available. The use of the IN6-8 pins for PWM control on the outputs 6-8 could generates bad diagnostic behavior when the falling edge of CS happens a short time after the falling edge of IN6-8 during the power MOS transient. Software filtering may be needed to ignore fault signals during Drn6-8 transient after falling edge of IN6-8. 7.2.2 Latch mode This diagnostic operating mode latches all faults when they happen. 1. Open load The diagnostic of open load is detected only in OFF condition sensing the Src1-8 output voltage. This fault is detected if the power drain voltage is inside the voltage range limited by the two thresholds Vth_Vbat and Vth_GND for the filtering time Tfilt. An internal current limited voltage regulator fixes the drain voltage inside the described range when no load is connected. 2. Short Circuit to Vb The diagnostic of short circuit to Vbat is detected only in OFF condition sensing the Src1-8 output voltage. This fault is detected if the power drain voltage is higher than the Vth_Vbat threshold for the filtering time Tfilt. 3. Overcurrent The diagnostic of overcurrent is detected only in ON condition, if the switching OFF protection of the channel is enabled (default), sensing the current level of the output power transistor. If the output current has been above the short threshold Iovc for the filtering time Tdel the output power is switched off and at the same time an overcurrent fault is written in the fault register. There are three possibilities to restart one output after the fault has occurred: – Automatically after a time Tres – On the rising edge of CS if two valid DI bytes have been received and first the Output Status in the command register is written with logic '0' and then with a logic “1” in the following SPI cycle – On the rising edge (low to high transition) at the corresponding parallel input pin (only for Outputs 6-8). If the switching OFF protection is not active the On phase overcurrent protection is a linear current limitation and no diagnosis is available. If the power MOS transient, after a switching-off command, is longer than Tdel filtering time, a bad diagnostic behavior happens and software filtering may be needed. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |