39 / 137 page ![]() 3.20 Temperature warning and shutdown If any of the cluster junction temperatures rises above the temperature warning threshold (TW ON), a temperature warning flag is set after the temperature warning filter time (tFTJTW) and can be read via SPI. If the junction temperature increases above the temperature shutdown threshold (TSD1 OFF), the thermal shutdown bit is set and the power transistors of all output stages are switched off to protect the device after the thermal shutdown filter time. The temperature warning and thermal shutdown flags are latched and must be cleared by the microcontroller. This is done by a read and clear command on the relevant status register (TSD1 is bit 4 in status register 1 while TW is bit 8 in status register 2). After these bits have been cleared, the output stages are reactivated. If the temperature is still above the thermal warning threshold, the thermal warning bit is set after tFTJTW. Once this bit is set and the temperature is above the temperature shutdown threshold, temperature shutdown is detected after tFTJTW and the outputs are switched off. Therefore, the minimum time after which the outputs are switched off after the bits have been cleared in case the temperature is still above the thermo shutdown threshold is twice the thermo warning/shutdown filter time tFTJTW. 3.21 Thermal clusters To provide an advanced on-chip temperature control, the power outputs are grouped in four clusters with dedicated thermal sensors. The sensors are suitably located on the device. In case the temperature of a cluster reaches the thermal shutdown threshold, the outputs assigned to this cluster are shut down (all other outputs remain active). Each output cluster has a dedicated temperature warning and shutdown flag (SR7 and SR8). Hence, the thermal cluster concept identifies a group of outputs in which one or more channels are in overload condition. If thermal shutdown has occurred within an output cluster, or if temperature is rising within a cluster, it may be desired to identify which of the output(s) is (are) determining the temperature increase. Thermal clusters can be configured using bit TSD_CLUSTER_EN (CR20): • Standard mode (default): as soon as any cluster reaches thermal threshold the device is switched off. V1 regulator remains on and is switched off reaching TSD2. All the thermal sensors are put in “OR”. In fact, if one of these sensors reaches TSD1: – All outputs drivers and V2 are turned OFF. – V1 remains on until TSD2. – LIN and CAN transmitter are turned OFF (but they are forced in "receive only" mode). • Cluster mode: only the cluster, which reached shutdown temperature is switched off. In case cluster Th_CL1 reaches TSD1: – V1 remains ON until TSD2 In case cluster Th_CL4 reaches TSD1. – All outputs drivers and V2 are turned OFF. – V1 remains on until TSD2. – LIN and CAN transmitter are turned OFF (but they are forced in "receive only" mode). SPSB081 Temperature warning and shutdown DS14048 - Rev 3 page 39/137 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |