| 数据搜索系统,热门电子元器件搜索 |
|
L99PM72GXPTR 数据表(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99PM72GXPTR 数据表(HTML) 32 Page - STMicroelectronics |
|
32 / 129 page ![]() Detailed description L99PM72GXP 32/129 DocID024767 Rev 4 2.8 LIN Bus Interface Features: • Speed communication up to 20kbit/s. • LIN 2.1 compliant (SAEJ2602 compatible) transceiver. • GND disconnection fail safe at module level. • Off mode: does not disturb network. • GND shift operation at system level. • Micro controller Interface with CMOS compatible I/O pins. • Internal Pull-up resistor • Internal High Side Switch to disconnect Master Pull-up resistor in case of short circuit of bus signal (b) • ESD and transient immunity according to ISO7637 and EN / IEC61000-4-2 • Matched output slopes and propagation delay In order to further reduce the current consumption in standby mode, the integrated LIN bus interface offers an ultra low current consumption. 2.8.1 Error handling The L99PM72GXP provides the following three error handling features which are not described in the LIN Spec. V2.1, but are realized in different stand alone LIN transceivers / micro controllers to switch the application back to normal operation mode. At VS >VPOR (i.e. VS power-on reset threshold), the LIN transceiver is enabled. The LIN transmitter is disabled in case of the following errors: • Dominant TxDL time out • LIN permanent recessive • Thermal Shutdown 1 • VS Over- / Undervoltage The LIN receiver is not disabled in case of any failure condition. Dominant TxDL time out If TXDL is in dominant state (low) for more than 12 ms (typ) the transmitter is disabled, the status bit is latched and can be read and optionally cleared by SPI. The transmitter remains disabled until the status register is cleared. This feature can be disabled via SPI. Permanent recessive If TXDL changes to dominant (low) state but RXDL signal does not follow within 40 µs the transmitter is disabled, the status bit is latched and can be read and optionally cleared by SPI. The transmitter remains disabled until the status register is cleared. b. Use of the Master Pull-up switch is optional. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |