| 数据搜索系统,热门电子元器件搜索 |
|
TMP442 数据表(PDF) 12 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP442 数据表(HTML) 12 Page - Texas Instruments |
|
12 / 57 page ![]() 7.4 Device Functional Modes The device can be configured to operate in different modes of operation through the configuration register or the filter and alert mode register. 7.4.1 Interrupt and Comparator Mode The ALERT pin of the device can be programmed into two different ALERT output modes. In the interrupt mode, the device asserts the ALERT pin if the temperature exceeds the limits set by the temperature limit registers. After the Alert Status is read and interrupt bits cleared, the ALERT pin is deasserted. In Comparator Mode, the device asserts the ALERT pin if the measured temperature exceeds the limits and clears when the temperature returns below the limits. 7.4.1.1 Interrupt Mode When the Alert Mode Setting bit in the Configuration Register is set to 0, the Alert Mode is set to Interrupt mode. In this mode, the ALERT pin is asserted at the end of a conversion cycle if the measured temperature exceeds a High Alert Limit or goes below a Low Alert Limit defined in the limit registers. In this mode, the TMP4719 sets the ALERT mask bit of the Configuration Register during a read of the Status Register if any flag in the Status Register, except the ADC_Busy flag and Remote Diode Open flag, is set. This prevents the ALERT pin from triggering until the controller has reset the ALERT mask bit (write 0 to the Alert_MASK bit). The ALERT High Status flags are set at the end of a conversion cycle when the measured temperature exceeds a High Alert Limit register limit. There are separate High Limit values and status register flags for the remote and local temperature measurements. The status register flags are only set to the respective temperature measurements. The ALERT Low Status flag is set at the end of a conversion cycle when the measured remote temperature is below the Remote Low Alert Limit register limit. There are separate Low Limit values and status register flags for the remote and local temperature measurements. The status register flags are only set to the respective temperature measurements. Refer to Section 8.30 . The Status Register limit flags are cleared after a read command of the Status Register from the controller and are set again at the end of a preceding temperature conversion cycle if the measured temperature is outside the set limits. Figure 7-5 shows the behavior of the ALERT pin and flags while in Interrupt mode. TMP4719 SBOSAJ7 – OCTOBER 2025 www.ti.com 12 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: TMP4719 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |