TLV3011AIDBVR 数据表(HTML) 4 Page - Texas Instruments |
|
4 / 41 page ![]() 6 Specifications 6.1 Absolute Maximum Ratings- TLV3011 and TLV3012 Over operating free-air temperature range (unless otherwise noted)(1). MIN MAX UNIT Supply voltage 7 V Signal input pins Voltage(2) –0.5 (V+) +0.5 V Current(2) ±10 mA Output short circuit(3) Continuous Operating temperature –40 125 °C TJ Junction temperature 150 °C Tstg Storage temperature –65 150 °C (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. (2) All voltage values are with respect to the network ground pin. (3) Short circuit to ground 6.2 Absolute Maximum Ratings - TLV3011B and TLV3012B over operating free-air temperature range (unless otherwise noted)(1) MIN MAX UNIT Supply voltage: VS = (V+) – (V–) –0.5 7 V Input pins (IN+, IN–) from (V–)(2) –0.5 7 V Output (OUT) (Open-Drain) from (V–)(3) –0.5 7 V Output (OUT) (Push-Pull) from (V–) –0.5 (V+) + 0.5 V Output short circuit current(4) 10 mA Junction temperature, TJ 150 °C Storage temperature, Tstg –65 150 °C (1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime. (2) Input pins are diode-clamped to (V–). Inputs (IN+, IN–) can be greater than (V+) as long as within the –0.5 V to 7 V range. Inputs beyond –0.3 V must be current-limited to less than –10 mA, while inputs beyond 7 V must be externally voltage clamped. (3) Output (OUT) for open drain can be greater than (V+) and inputs (IN+, IN–) as long as it is within the –0.5 V to 7 V range (4) Short-circuit to (V–) or (V+). 6.3 ESD Ratings VALUE UNIT V(ESD) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1) ±2000 V Charged-device model (CDM), per ANSI/ESDA/JEDEC JS-002(2) ±1000 (1) JEDEC document JEP155 states that 500 V HBM allows safe manufacturing with a standard ESD control process. (2) JEDEC document JEP157 states that 250 V CDM allows safe manufacturing with a standard ESD control process. TLV3011, TLV3012, TLV3011B, TLV3012B SBOS300C – FEBRUARY 2004 – REVISED APRIL 2023 www.ti.com 4 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: TLV3011 TLV3012 TLV3011B TLV3012B |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |