| 数据搜索系统,热门电子元器件搜索 |
|
PP002145 数据表(PDF) 3 Page - Multicomp Pro |
|
|
|||||||||||||||||||||||||||||
PP002145 数据表(HTML) 3 Page - Multicomp Pro |
|
3 / 4 page ![]() Page <3> V1.0 08/04/20 H07RN-F / BS EN 50525-2-21 Flexible Rubber Cable Newark.com/multicomp-pro Farnell.com/multicomp-pro Element14.com/multicomp-pro Nominal Cross Sectional Area mm2 60°C Conductor Operating Temperature 85°C Conductor Operating Temperature** Single-Phase AC or DC Three-Phase AC Single-Phase AC or DC Three-Phase AC 1 Two Core Cable, With or Without Protective Conductor Amps 1 Three Core, Four Core or Five Core Cable Amps 1 Two Core Cable, With or Without Protective Conductor Amps 1 Three Core, Four Core or Five Core Cable Amps 4 30 26 41 36 6 39 34 53 47 Nominal Cross Sectional Area mm2 Two Core Cable, DC mV/A/m Two Core Cable, Single-Phase AC mV/A/m 1 Three Core, Four Core Or Five Core Cable, Three-Phase AC mV/A/m 4 12 12 10 6 7.8 7.8 6.7 Electrical Characteristics (4mm2 and above) Current Carrying Capacity Voltage Drop Ambient temperature: 30°C Conductor operating temperature: 60°C / 85°C The above table for 60°C conductor operating temperature is in accordance with Table 4F1A of the 17th Edition of IEE Wiring Regulations ** 85°C Table is in accordance with Table 4H2A of the 16th Edition of IEE Wiring Regulations. The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. If the cable is to be wound on a drum on load the ratings should be reduced in accordance with NOTE 2 below and for cables which may be covered, NOTE 3 below. 2. Flexible cables wound on reeling drums The current ratings of cables used on reeling drums are to be reduced by the following factors: a) Radial type drum b) Ventilated cylindrical type drum ventilated: 85% 1 layer of cable: 85% unventilated: 75% 2 layers of cable: 65% 3 layers of cable: 45% 4 layers of cable: 35% A radial type drum is one where spiral layers of cable are accommodated between closely spaced flanges; if fitted with solid flanges the ratings given above should be reduced and the drum is described as non-ventilated. If the flanges have suitable apertures the drum is described as ventilated. A ventilated cylindrical cable drum is one where layers of cable are accommodated between widely spaced flanges and the drum and end flanges have suitable ventilating apertures. 3. Where cable may be covered or coiled up whilst on load, or the air movement over the cable restricted, the current rating should be reduced. It is not possible to specify the amount of reduction but the table of rating factors for reeling drums can be used as a guide. Conductor operating temperature: 60°C |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |