| 数据搜索系统,热门电子元器件搜索 |
|
U2000/1/2H 数据表(PDF) 10 Page - Keysight Technologies |
|
|
|||||||||||||||||||||||||||||
U2000/1/2H 数据表(HTML) 10 Page - Keysight Technologies |
|
10 / 26 page ![]() Specifications (continued) Switching point The U2000 Series power sensors have two measurement paths: a low power path and a high power path, as shown in the table below. Models AUTO (default) range Low power path High power path Switching point U2000/1/2/4A –60 to +20 dBm –60 to –7 dBm –7 to +20 dBm –7 dBm U2000/1/2H –50 to +30 dBm –50 to +3 dBm +3 to +30 dBm +3 dBm U2000/1B –30 to +44 dBm –30 to +23 dBm +23 to +44 dBm +23 dBm Each power sensor automatically selects the proper power level path. To avoid unnecessary switching when the power level is close to the switch- ing point, switching point hysteresis has been added. Offset at switching point: ≤ ± 0.5% (≤ ± 0.02 dB) typical Switching point hysteresis: ± 0.5 dBm typical Example with U2000 “A” suffix sensors: Switching point for the U2000/1/2/4A sensors is at –7 dBm. Hysteresis causes the low power path to remain selected until approxi- mately –6.5 dBm as the power level is increased. Above this power, the high power path is selected. The high power path remains selected until approximately –7.5 dBm is reached as the signal level decreases. Below this power, the low power path is selected. Power accuracy Average only Mode Power Accuracy1 (with exclusions) Model Power range Accuracy1 (25 °C ± 10 °C) Accuracy1 (0 °C to 55 °C) U2000/1/2/4A –60 to +20 dBm ±3.0% ±3.5% U2000/1/2H –50 to +30 dBm ±4.0% ±5.0% U2000/1B –30 to +44 dBm ±3.5% ±4.0% Specifications valid with the following conditions: – After zeroing3 – Number of averages = 1024 – After 30 minutes of power-on warm-up Normal Mode Power Accuracy1, 2 (with exclusions) Model Power level Accuracy (25 °C ± 10 °C) U2000/1/2/A –30 to +20 dBm ±4.0% U2000/1/2H –20 to +30 dBm ±5.0% U2000/1B 0 to +44 dBm ±4.5% 1. This accuracy is essentially a combination of linearity, instrumentation accuracy, and traceability to absolute accuracy at 50 MHz, 0 dBm. Note: Mismatch uncertainty, calibration factor uncertainty, and power level dependent terms (zero set, drift, and noise) are excluded in this specification and specified elsewhere in the data sheet. 2. The accuracy for –7 to +1 dBm (U2000/1/2A), +3 to +11 dBm (U2000/1/2H), and +23 to +31 dBm (U2000/1B) power level will be dominated by zero set and measurement noise. For overall accuracy, refer to the measurement uncertainty calculator which is available on the Keysight Technologies Web site. 3. It is advisable to perform external zeroing on the U2000 Series power sensor for power measurement level below –30 dBm. During the exter- nal zeroing process, the RF input signal must be switched off or the device-under-test disconnected from the U2000 Series power sensor. 10 | Keysight | U2000 Series USB Power Sensors - Data Sheet |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |