| 数据搜索系统,热门电子元器件搜索 |
|
L9349 数据表(PDF) 6 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9349 数据表(HTML) 6 Page - STMicroelectronics |
|
6 / 12 page ![]() L9349 6/12 DIAGNOSTIC TABLE CIRCUIT DESCRIPTION The L9349 is a quad low side driver for inductive loads like valves in automotive environment. The internal pull down current sources at the ENable and INput pins assure in case of open input conditions that the device is switched off. An output voltage slope limitation for du/dt is implemented to reduce the EMI. An integrated active flyback voltage limitation clamps the output voltage during the flyback phase to 50 V. Each driver is protected against short circuit at VOUT < 32V and thermal overload. In short circuit condition the output will be disabled after a short delay time tDOL. The thermal disable for TJ > 180°C of the output will be reset if the junction temperature decreases about 20°C below the disable threshold temperature. The overtemperature, overload and groundloss information is stored until IN is low. For the real time error diagnosis the voltage and the current of the outputs are compared with internal fixed val- ues VOUV for OFF and IOUC for ON conditions to recognize open load (RL ≥ 20KΩ, RL > 38Ω) in OFF and ON conditions. Also the output voltages VO1- 4 are compared to each other output in OFF condition with a fixed offset of ∆VOUV to recognize load bypasses. The ∆VOUV diagnoses is suppressed during the flyback phases of the compared output. The outputs 1 and 4 are compared for ∆VOUV and also outputs 2 and 3 are compared. The diagnostic output level in connection with different ENable and INput conditions allows to recognize differ- ent fail states, like overtemp, short to VS, short to GND, bypass to GND and disconnected load (see diagnostic table). The diagnostic output is protected against short circuit. Exceeding the over load current threshold IOOC, the out- put current will be limited internally during the diagnostic overload delay switch-off time tDOL. The device complies the ISO pulses imposed to the supply voltage of the valves without any failures of the func- tionality. Therefore some diagnostic functions are internal filtered. The following table shows the corresponding filter time for each detected signal. Conditions EN IN OUT DIAG. Normal Function L X off L HL off L HH on H GND short VOtyp < 0.55VS L X off H Load bypass ∆VO1-4/2-3 ≥ 1.25V HL off H Open Load IO1,2,3,4typ < 320mA HH on L Tjtyp ≥ 190°C Overtemperature XX off L Over Load IOmin 1,2 > 5A IOmin 3,4 > 3A HH off L SGND or PGND loss channel off X L off H SGND or PGND loss channel on H H off L |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |