2 / 4 page ![]() www.bkprecision.com General Accessories Oscilloscope Probes Applications ■ ■ Switching power supply designs ■ ■ Motor drive design ■ ■ Electronic ballast design Specifications PR-60 Bandwidth 25 MHz (-3 dB) Attenuation ratio x10/x100 Accuracy ±2% Rise time 14 ns Input impedance 4 MΩ/10 pF each side to ground Input voltage Max. differential ±700 V (DC+Peak AC) Max. common mode ±700 V (DC+Peak AC) Output voltage Max. amplitude ±7 V (into 2 kΩ load) Offset (Typical) ≤±5 mV, -10°to 40° C Noise (Typical) 1.5 to 2 mV Source impedance 1 Ω @ 1 kHz 8 Ω @ 1 MHz CMRR 50Hz 86 dB 20kHz 66 dB 200kHz 56 dB Probes Sprung hooks (B/R) Length of input lines 45 cm Operating temperature 14° to 104°F (-10° to 40°C) Power requirements 4 x AA batteries Certification IEC61010-1 CATIII General Purpose Passive Probes This full line of probes increases the versatility of your oscilloscope with both fixed and switchable attenuation. Each probe includes a full accessory kit with a sprung hook, replacement tip and BNC adapter. All models are compliant to IEC61010-031. Specifications Passive probes High voltage (passive) PR 33A PR 37 AG PR 37AR PR 100A PR-55 Bandwidth (MHz) 15/90 6/150 6/150 250 50 Attenuation x1/x10 x1/x10/REF x1/x10/REF x100 x1000 Input impedance R(MΩ) 1/10 1/10 1/10 100 100 Capacitance (pF) 46/16 100/15 100/15 6.5 1 Voltage (VDC+AC max) 600 600 600 1,200 10,000 Compensation (pF) 10-35 10-35 10-35 10-35 10-30 Cable length 1.2 m 1.2 m 1.2 m 1.2 m 2.0 m Model PR-55 Model PR 37AR PR 32A RF Detector Probe Specifications PR 32 A Bandwidth 100 kHz - 950 MHz Accuracy ±3 dB Voltage 200 V HF voltage 50 Veff Actuating Voltage 250 mV Input capacitance 5 pF Cable length 1.2 m Body color Black Specifications PR150B PR250B PR500B PR2000B Type 5 mm Passive Voltage Bandwidth 17/150 MHz 250 MHz 500 MHz 200 MHz Attenuation 1x/10x 10x 10x 100x Input impedance 1/10 MΩ 10 MΩ 10 MΩ 100 MΩ Input capacitance ≈45/12 pF ≈12 pF ≈10 pF ≈5 pF Rise time 20/2.3 ns 1.4 ns 0.7 ns 1.8 ns IEC rating 300 V CAT II 300 V CAT II 300 V CAT II 2,000 V CAT I Compensation 10−30 pF 10−30 pF 6–22 pF 10−30 pF Cable length 1.2 m Attenuation accuracy - - - 6% Voltage coefficient (VCR) - - - ≤30 ppm/V Operating temperature 0° to +50° C Humidity 85% RH or less (at 35° C) PR-60 Active Differential Probe Allows for safe and accurate floating measurements with your standard analog or digital oscilloscope. Passive Oscilloscope Probes High bandwidth, high impedance 10x passive voltage probe with 10 MΩ input impedance. All probes are RoHS (2002/95/EC) compliant. 69 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |