3 / 16 page ![]() Dual, 2-Wire Hall-Effect Sensor Interface with Diagnostics _______________________________________________________________________________________ 3 Note 1: All DC specifications are 100% tested at TA = +25°C. AC specifications and specifications over -40°C to +125°C are guar- anteed by design. Note 2: CL is external load capacitance on the outputs for test only. Note 3: These blanking times apply when the MAX9921 is operating in normal mode. Blanking times following power-up or startup from shutdown mode are 20µs longer. Note 4: The following AC parameters change with the value of RISET: tBL, tRAMP, tDEL, fMAX, and PR. The typ values given are for RISET = 63.4kΩ. The parameters tRAMP and fMAX increase 8%, and tDEL and PR decrease 8% with RISET = 59.0kΩ. The lim- its for tBL and fMAX apply for both resistor values. AC TIMING CHARACTERISTICS (VBAT = 13.6V, VDIAG = 0, VOE = 5V, IN1 = IN2 = no connection, RISET = 63.4kΩ, RPU = 10kΩ at ERR, OUT1 and OUT2, TA = -40°C to +125°C, unless otherwise noted. Typical values are at TA = +25°C.) (Notes 1, 2, and 4) DC ELECTRICAL CHARACTERISTICS (continued) (VBAT = 13.6V, VDIAG = 0, VOE = 5V, IN1 = IN2 = no connection, RISET = 63.4kΩ, RPU = 10kΩ at ERR, OUT1 and OUT2, TA = -40°C to +125°C, unless otherwise noted. Typical values are at TA = +25°C.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS IN1, IN2 Blanking Time at Hall Switch Power-Up tBL IIH = -11.5mA to GND, time from VIN_ = 500mV until OUT_ high, CL = 20pF (Note 3) 50 140 µs IN1, IN2 Current Ramp Rate After Turn-On tRAMP VIN = GND 3.8 mA/µs Delay from IN_ to OUT_ (Filter Delay) tDEL From IIH to IIL or from IIL to IIH, CL = 20pF, Figure 1 6.5 µs Delay from IN_ Fault to ERR tERR From IIL to ISC or from IIH to IOC, falling edge only, CL = 20pF, Figure 1 31 ns Delay from DIAG High to OUT_ and ERR tDLH Rising edge of DIAG to falling or rising edge of outputs, CL = 20pF, Figure 1 350 ns Delay from DIAG Low to OUT_ and ERR tDHL Falling edge of DIAG to falling or rising edge of outputs, CL = 20pF, Figure 1 1.6 µs Delay Difference Between Rising and Falling Edges for Both Channels tDM CHALL-BYPASS = 0.01µF, IIH = -11.5mA and IIL = -7.2mA, CL = 20pF 20 ns Delay Difference Between Channels tCC CHALL-BYPASS = 0.01µF, IIH = -11.5mA and IIL = -7.2mA, CL = 20pF 100 ns Maximum Frequency on Hall Inputs fMAX CHALL-BYPASS = 0.01µF, IIH = -11.5mA and IIL = -7.2mA, CL = 20pF 50 kHz IN_ Pulse Length Rejected by Filter to OUT_ PR Figure 2 5.5 µs PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS LOGIC I/O (OUT1, OUT2, ERR, DIAG, and OE) Output Voltage Low (ERR, OUT1, OUT2) VOL Sink current = 1mA 0.4 V Three-State Output Current (ERR, OUT1, OUT2) IOZ VOE = 0V, 0 ≤ VOUT_ ≤ 5V ±1 µA Input-Voltage High (DIAG, OE) VIH 2.1 V Input-Voltage Low (DIAG, OE) VIL 0.8 V Input Resistance to GND (DIAG, OE) RIN 50 80 k Ω |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |