13 / 63 page ![]() 7.3.5 Digital Filter Remote junction temperature sensors are typically implemented in a noisy environment. Noise is most often created by fast digital signals that can corrupt measurements. A digital filter is available for the remote temperature measurements to reduce the effect of noise. This filter is programmable and has two levels when enabled. Level 1 performs a moving average of four consecutive samples. Level 2 performs a moving average of eight consecutive samples. After POR, the output of the digital filter starts with a default ZERO without previous data. The output of the digital filter is stored in the remote temperature result register, and the temperature limits are compared to this value. The filter responses to impulse and step inputs are shown in Figure 7-3 and Figure 7-4, respectively. The filter can be enabled or disabled by programming the desired levels in register settings. The digital filter is disabled by default. The averages are cleared after the filter is set to 00h. Filtering can be used with both continuous conversions and one-shot conversions. 0 10 20 30 40 50 60 70 80 90 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Samples Disabled Level1 Level 2 Figure 7-3. Filter Response to Impulse Inputs 0 10 20 30 40 50 60 70 80 90 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Samples Disabled Level 1 Level 2 Figure 7-4. Filter Response to Step Inputs In addition to the built-in digital filter of the device, TI recommends the user add an external capacitor between the DP and DN pins on the remote channel. The capacitor acts as a bypass filter to help reduce high-frequency EMI noise when the device is operating in a noisy environment. The recommended optimal value for the capacitor is 470pF, and the value must not exceed 3nF to allow proper operation of the temperature sensor. 7.3.6 One-Shot Conversions Users can write any data to the one-shot register to trigger a manual single one-shot conversion. This allows for greater control of the device and flexibility of system implementation. This feature is only available in Shutdown mode, and writes to the one-shot register has no effect in continuous conversion mode. For best performance in one-shot mode, have the communication bus idle during temperature conversion (within tCONV after a conversion is triggered). www.ti.com TMP4719 SBOSAJ7A – OCTOBER 2025 – REVISED DECEMBER 2025 Copyright © 2025 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: TMP4719 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |