| 数据搜索系统,热门电子元器件搜索 |
|
M58LR128KB855 数据表(PDF) 21 Page - Numonyx B.V |
|
|
|||||||||||||||||||||||||||||
M58LR128KB855 数据表(HTML) 21 Page - Numonyx B.V |
|
21 / 110 page ![]() M58LR128KT, M58LR128KB, M58LR256KT, M58LR256KB Command interface 21/111 4.5 Clear Status Register command The Clear Status Register command resets (set to ‘0’) all error bits (SR1, 3, 4 and 5) in the Status Register. One bus write cycle is required to issue the Clear Status Register command. The Clear Status Register command does not affect the read mode of the bank. The error bits in the Status Register do not automatically return to ‘0’ when a new command is issued. The error bits in the Status Register should be cleared before attempting a new program or erase command. 4.6 Block Erase command The Block Erase command erases a block. It sets all the bits within the selected block to ’1’. All previous data in the block is lost. If the block is protected then the erase operation aborts, the data in the block does not change and the Status Register outputs the error. Two bus write cycles are required to issue the command. ● The first bus cycle sets up the Block Erase command. ● The second latches the block address and starts the Program/Erase Controller. If the second bus cycle is not the Block Erase Confirm code, Status Register bits SR4 and SR5 are set and the command is aborted. Once the command is issued the bank enters Read Status Register mode and any read operation within the addressed bank outputs the contents of the Status Register. A Read Array command is required to return the bank to read array mode. During block erase operations the bank containing the block being erased only accepts the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend commands; all other commands are ignored. The block erase operation aborts if Reset, RP, goes to VIL. As data integrity cannot be guaranteed when the block erase operation is aborted, the block must be erased again. Refer to Section 8: Dual operations and multiple bank architecture for detailed information about simultaneous operations allowed in banks not being erased. Typical erase times are given in Table 18: Program/erase times and endurance cycles. See Appendix C, Figure 22: Block erase flowchart and pseudocode for a suggested flowchart for using the Block Erase command. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |