| 数据搜索系统,热门电子元器件搜索 |
|
1237000000 数据表(PDF) 3 Page - Weidmuller |
|
|
|||||||||||||||||||||||||||||
1237000000 数据表(HTML) 3 Page - Weidmuller |
|
3 / 7 page ![]() Data sheet SCZ 3.81/04/180GZE SN OR BX Weidmüller Interface GmbH & Co. KG Klingenbergstraße 26 D-32758 Detmold Germany www.weidmueller.com Technical data Comparative Tracking Index (CTI) ≥ 550 Moisture Level (MSL) UL 94 flammability rating V-0 Contact material Copper alloy Contact surface tinned Layer structure of plug contact 4...8 µm Sn Storage temperature, min. -40 °C Storage temperature, max. 70 °C Operating temperature, min. -50 °C Operating temperature, max. 120 °C Temperature range, installation, min. -25 °C Temperature range, installation, max. 120 °C Conductors suitable for connection Clamping range, min. 0.08 mm² Clamping range, max. 1.5 mm² Wire connection cross section AWG, min. AWG 28 Wire connection cross section AWG, max. AWG 16 Solid, min. H05(07) V-U 0.2 mm² Solid, max. H05(07) V-U 1.5 mm² Flexible, min. H05(07) V-K 0.2 mm² Flexible, max. H05(07) V-K 1.5 mm² w. plastic collar ferrule, DIN 46228 pt 4, min. 0.2 mm² w. plastic collar ferrule, DIN 46228 pt 4, max. 1.5 mm² w. wire end ferrule, DIN 46228 pt 1, min. 0.2 mm² w. wire end ferrule, DIN 46228 pt 1, max. 1.5 mm² Plug gauge in accordance with EN 60999 a x b; ø 2.4 mm x 1.5 mm ; 2.4 mm Clampable conductor Cross-section for conductor connection Type fine-wired nominal 0.5 mm² wire end ferrule Stripping length nominal 6 mm Recommended wire- end ferrule H0,5/6 Cross-section for conductor connection Type fine-wired nominal 0.75 mm² wire end ferrule Stripping length nominal 6 mm Recommended wire- end ferrule H0,75/6 Cross-section for conductor connection Type fine-wired nominal 1 mm² wire end ferrule Stripping length nominal 6 mm Recommended wire- end ferrule H1,0/6 Cross-section for conductor connection Type fine-wired nominal 1.5 mm² wire end ferrule Stripping length nominal 7 mm Recommended wire- end ferrule H1,5/7 Reference text The outside diameter of the plastic collar should not be larger than the pitch (P), Length of ferrules is to be chosen depending on the product and the rated voltage. Rated data acc. to IEC tested acc. to standard IEC 60664-1, IEC 61984 Rated current, min. number of poles (Tu=20°C) 17.5 A Rated current, max. number of poles (Tu=20°C) 17.1 A Rated current, min. number of poles (Tu=40°C) 17.5 A Creation date 27.02.2026 10:52:02 MEZ Catalogue status / Drawings 3 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |