| 数据搜索系统,热门电子元器件搜索 |
|
M41T256YMT7 数据表(PDF) 15 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T256YMT7 数据表(HTML) 15 Page - STMicroelectronics |
|
15 / 27 page ![]() 15/27 M41T256Y Power-on Reset The M41T256Y continuously monitors VCC. When VCC falls to the power fail detect trip point, the RST pulls low (open drain) and remains low on power- up for tREC after VCC passes VPFD (max). The RST pin is an open drain output and an appropriate pull-up resistor should be chosen to control rise time. Tamper Indication Circuit The M41T256Y provides an independent input pin, the Tamper Pin (TP) which can be used to monitor a signal which can result in the setting of the Tamper Bit (TB) if the Tamper Enable Bit (TEB) is set to a '1.' The Tamper Pin is triggered by being connected to VCC/VBAT through an external switch. This switch is normally open in the application, allowing the pin to be “floating” (internally latched to VSS when TEB is set). When this switch is closed (connecting the pin to VCC/VBAT), the Tamper Bit will be immedi- ately set. This allows the user to determine if the device has been physically moved or tampered with. The Tamper Bit is a “read only” bit and is re- set only by taking the Tamper Pin to ground and resetting the Tamper Enable Bit to '0.' This function operates both under normal power, and in battery back-up. If the switch closes during a power-down condition, the bit will still be set cor- rectly. Note: Upon initial battery attach or initial power application without the battery, the state of TEB (and TB) will be undetermined. Therefore TEB must be initialized to a '0.' Tamper Event Time-Stamp If a tamper occurs, not only will the Tamper Bit be set, but the event will also automatically be time- stamped. This is accomplished by freezing the normal update of the clock registers (7FF7h through 7FFFh) immediately following a tamper event. Thus, when tampering occurs, the user may first read the time registers to determine exactly when the tamper event occurred, then re-enable the clock update to the current time (and reset the Tamper Bit, TB) by resetting the Tamper Enable Bit (TEB). The time update will then resume, and after either a Stop Condition or incrementing the address pointer to a RAM address and back, the clock can be read to determine the current time. Note: The Tamper Bit (TB) must always be set to '0' in order to read the current time. Calibrating the Clock The M41T256Y is driven by a quartz controlled os- cillator with a nominal frequency of 32,768Hz. The devices are tested not exceed ±35 ppm (parts per million) oscillator frequency error at 25oC, which equates to about ±1.53 minutes per month. When the Calibration circuit is properly employed, accu- racy improves to better than +1/–2 ppm at 25°C. The oscillation rate of crystals changes with tem- perature (see Figure 14., page 16). Therefore, the M41T256Y design employs periodic counter cor- rection. The calibration circuit adds or subtracts counts from the oscillator divider circuit at the di- vide by 256 stage, as shown in Figure 15., page 16. The number of times pulses which are blanked (subtracted, negative calibration) or split (added, positive calibration) depends upon the value loaded into the five Calibration bits found in the Control Register. Adding counts speeds the clock up, subtracting counts slows the clock down. The Calibration bits occupy the five lower order bits (D4-D0) in the Control Register (7FF8h). These bits can be set to represent any value be- tween 0 and 31 in binary form. Bit D5 is a Sign Bit; '1' indicates positive calibration, '0' indicates nega- tive calibration. Calibration occurs within a 64 minute cycle. The first 62 minutes in the cycle may, once per minute, have one second either shortened by 128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2 minutes in the 64 minute cycle will be modified; if a binary 6 is loaded, the first 12 will be affected, and so on. Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator cycles for every 125,829,120 actual oscillator cycles, that is +4.068 or –2.034 ppm of adjustment per calibra- tion step in the calibration register. Assuming that the oscillator is running at exactly 32,768Hz, each of the 31 increments in the Calibration byte would represent +10.7 or –5.35 seconds per month which corresponds to a total range of +5.5 or –2.75 minutes per month. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |