| 数据搜索系统,热门电子元器件搜索 |
|
EPP-R1016 数据表(PDF) 53 Page - ABB |
|
|
|||||||||||||||||||||||||||||
EPP-R1016 数据表(HTML) 53 Page - ABB |
|
53 / 75 page ![]() 54 PROTEC TA PLUS MCB DIS TR IBUTION B OA R D 2 5 0A — MCB S 200 Series technical features General data Specifications S 200 M S 200P Standards IEC/EN 60898-1, IEC/EN 60947-2 IEC/EN 60898-1, IEC/EN 60947-2 UL 1077, CSA 22.2 No. 235 UL 1077, CSA 22.2 No. 235 Poles – 1P, 2P, 3P, 4P, 1P+N, 3P+N Tripping characteristics – B, C, D, K, Z B, C, D, K, Z Rated current In A 0.5...63A – Rated current f Hz 50/60Hz 50/60Hz Rated insulation voltage Ui acc. to IEC/EN 60664-1 – 440V AC (phase to phase) 250 V AC (phase to ground), 500 V AC (phase to phase) Overvoltage category – III – Pollution degree – 3 2 Data acc. to IEC/EN 60898-1 (except S200M UC data acc. to IEC/EN60898-2) Rated operational voltage Un V 1P: 230/400V AC; 1P+N: 230V AC ; 2... 4P: 400V AC; 3P+N: 400V 1P: 230V AC, 220V DC 2P: 400V AC, 440V DC 3...4P: 400V AC* Max. power frequency recovery voltage (Umax) V 1P: 253V AC; 1P+N: 253V AC; 2P: 440V AC; 3...4P: 440V AC; 3P+N: 440V AC 1P: 230V AC, 220V DC 2P: 400V AC, 440V DC 3...4P: 400V AC* Min. operating voltage V 12V AC - 12V DC – Rated short-circuit capacity Icn kA 10kA ≤ 25A: 25kA > 25A: 15kA Energy limiting class (B, C up to 40 A) – 3 3 Rated impulse withstand voltage Uimp. (1.2/50μs) kV – – Dielectric test voltage kV 2kV (50/60Hz, 1 min.) 2kV (50/60Hz, 1 min.) Reference temperature for tripping characteristics oC B, C, D: 30°C 30°C Electrical endurance ops. In < 32A: 20,000 ops (AC), In ≥ 32A: 10,000 ops. (AC); 1,000 ops. (DC); – Data acc. to IEC/EN 60947-2 Rated operational voltage Ue V 1P: 230V AC; 1P+N: 230V AC; 2...4P: 400V AC; 3P+N: 400V AC Max. power frequency recovery voltage (Umax) V 1P: 253V AC; 1P+N: 253V AC; 2P...4P: 440V AC; 3P+N: 440V AC; 1P: 72V DC; 2P: 125V DC Min. operating voltage V 12V AC - 12V DC 12 V AC - 12V DC Rated ultimate short-circuit breaking capacity Icu kA 15kA ≤ 25A: 25kA ≥ 32A: 15kA Rated service short-circuit breaking capacity Ics kA ≤ 40A: 11.2kA 50, 63A: 7.5kA ≤ 25A: 12.5kA ≤ 32…40A: 11.2kA 50, 63A: 7.5kA Rated impulse withstand voltage Uimp. (1.2/50μs) kV 4kV (test voltage 6.2kV at sea level, 5kV at 2,000m) – Dielectric test voltage kV 2kV (50/60Hz, 1 min.) – Reference temperature for tripping characteristics °C B, C, D: 55°C; K, Z: 20°C B, C: 55°C; K, Z: 20°C Electrical endurance ops. In < 32A: 20,000 ops (AC), In ≥ 32A: 10,000 ops. (AC); 1,000 ops. (DC); (1 cycle 2s - ON, 13s - OFF, In ≤ 32A), (1 cyle 2s - ON, 28s - OFF, In > 32A) In < 32A: 20,000 ops (AC), In ≥ 32A: 10,000 ops. (AC); 1,000 ops. (DC); (1 cycle 2s - ON, 13s - OFF, In ≤ 32A), (1 cyle 2s - ON, 28s - OFF, In ≥ 32A) Note: * Only acc. to IEC/EN 60898-1 r switching — Technical features |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |