| 数据搜索系统,热门电子元器件搜索 |
|
CFW2000 数据表(PDF) 2 Page - TOKYO KEISO CO.,LTD. |
|
|
|||||||||||||||||||||||||||||
CFW2000 数据表(HTML) 2 Page - TOKYO KEISO CO.,LTD. |
|
2 / 6 page ![]() TG-F2557-E00 CFW2000 Series PORTABLE AND DETACHABLE 2 TOKYO KEISO CO., LTD. MODEL CODE STANDARD SCALE RANGE ●The example of PVC lining pipe or non-standard pipes [example 2] Code number of CFIW2222 indicator with scale range for 50 mm of PVC lining pipe has [CFIW2222-5000-10-B/PL] and likewise with scale range for 50mm of non-standard pipes has [CFIW2222-5000-10-B/Z]. It has one graduation (for one size of pipe) as shown at the right drawing. CFIW2 □ 2 □ -□□□□ -□0 -B /□□□ Description 2 Horizontal Installation type 4 Vertical Indicator calibration 2 7°C and 60°C water, double scale 1 Scale range 1 See right table Scale range 2 Scale range 2 See right table -1000 -2000 -3000 -4000 -5000 -6000 -7000 -8000 -9000 -A000 *1 PVC lining type is available only for the size 32 mm to 150 mm with 1 MPa class. -B000 -C000 -D000 -E000 -F000 Note 1 Main pipe size and combination of 4 measuring pipe sizes -G000 -10 1 MPa class Pressure rating -20 2 MPa class Version -B Version code /DEG Degreasing treatment Option /PL For the PVC lining pipe blank 欄 Not provided Additional function /Z Provided CFNW □□□ -□ -B Description 020 20 mm 025 25 mm 032 32 mm 040 40 mm 050 50 mm 065 65 mm 080 80 mm 100 100 mm 125 125 mm 150 150 mm *1 PVC lining type is available only for the size 32 mm to 150 mm. 200 200 mm 250 250 mm 300 300 mm 350 350 mm 400 400 mm Main pipe size 450 450 mm Pressure rating -2 Pressure rating code Version -B Version code /CFT Three-way socket for 20 to 32 mm Applied to only Indicator CFIW 1MPa class /CFS Socket of welding for 40 mm or larger pipes /DEG Degreasing treatment /COV Dew prevention cover /BC6 Material of fitting is CAC406 Option /PL For PVC lining pipe blank Not provided Additional function /Z Provided ●The example of standard specification [example 1] Code number of CFIW2221 indicator with Scale range 1 for 25, 50, 200, 300mm sizes has [CFIW2221-25BD-□ 0-B]. Scales can be chosen. The graduation example is shown in right drawing. One piece of CFIW indicator is able to have 4 different scale ranges. But for the cases of PVC lining pipe (option code: /PL) and pipe with non-standard inside diameter, one indicator has one scale range. 50A COLDHO T 300 0 3 0 25A COLDHO T 150 0 5 A COLDH OT 500 5 1 0 0 5 0 Inside diameter of pipe mm Size Scale range L/min mm inch Scale range 1 *2 Scale range 2 *1, *2 1 MPa class *3, *5 2 MPa class *4, *5 PVC lining pipe *1 20 3/4 12 to 100 [8 to 75] 10 to 60 [6 to 45] (26) (21.4) 25 1 18 to 150 [13 to 120] 15 to 100 [10 to 75] (34) (27.2) 25 to 180 32 11/4 35 to 280 [25 to 220] [20 to 140] (43) (35.5) 29.5 40 11/2 35 to 300 30 to 180 41.6 41.2 34.7 50 2 60 to 500 50 to 300 52.9 52.7 46.2 65 21/2 100 to 800 80 to 500 67.9 65.9 59.7 80 3 150 to 1200 120 to 700 80.7 78.1 70.9 100 4 250 to 2000 200 to 1200 105.3 102.3 95.2 125 5 400 to 3000 300 to 2000 130.8 126.6 119.7 150 6 600 to 4500 400 to 2800 155.2 151.0 142.0 200 8 1000 to 8000 700 to 4800 204.7 199.9 250 10 1500 to 12000 1200 to 7500 254.2 248.8 300 12 2000 to 17000 1600 to 10000 304.7 297.9 350 14 2500 to 22000 2000 to 13000 339.8 333.4 400 16 3500 to 28000 2800 to 17000 390.6 381.0 450 18 4500 to 35000 3500 to 22000 441.4 428.6 *1 PVC lining type is available for the size 32 mm to 150 mm as marked gray. Its scale range is shown in the column Scale range 2 as marked gray. Full-scale flow rates for the PVC lining pipe are calculated based on the inner diameter of ESLON® ESLOCOAT LX tee fittings (Sekisui Chemical Co., Ltd). The maximum rating is 1 MPa. If you use other fittings, additional calibration is needed. Please check “D” and “L” in the figure at the end of this document and the kind of pipe, and then contact us. *2 Scale ranges of 20, 25, 32 mm size for 2 MPa class are shown in the brackets in above table. *3 The inside diameter of main pipe of 20 to 32mm in 1MPa class is based on the three-way socket (JIS B 2301).(The three-way socket shall be attached upon request.) *4 The inside diameter of main pipe of 20 to 32mm in 2 MPa class is based on three-way socket (Sch 40). The three-way socket is supplied by customer. *5 The inside diameter of main pipe more than 40mm in 1 MPa class is based on SGP (JIS G3452) Carbon steel pipe for piping, and the inside diameter in 2 MPa class is based on the carbon steel pipe for STPG (JIS G 3454 Sch 40) for pressure piping. Scale 4 Scale 1 Scale 2 Scale 3 This can be rotated freely Sight glass Tapered tube ● CFIW Indicator The CFW2000 “ONE-TOUCH FLOW” is composed of : - A CFIW indicator - A CFNW fixing nozzle - A three-way socket (for main pipe size 20 to 32 mm) or a socket for welding piping (for main pipe size 40 mm or larger) Scale for 20 mm Scale for 25 mm Scale for 32 mm Scale for 40 mm Scale for 50 mm Scale for 65 mm Scale for 80 mm Scale for 100 mm Scale for 125 mm Scale for 150 mm Scale for 200 mm Scale for 250 mm Scale for 300 mm Scale for 350 mm Scale for 400 mm Scale for 450 mm ● CFNW Fixing nozzle /□□□ Note1 Example ① The combination of 4 measuring pipes: The combined code of 4 measuring pipes for 25, 50, 200, 300 mm is “-25BD”. The whole model code becomes “CFIW2□2□-25BD-□0-B ”. Example ② The combination of 3 measuring pipes or less: The combined code of 3 measuring pipes for 100, 125, 150 mm is “-89A0”. The whole model code becomes “CFIW2□2□-89A0-□0-B ”. CFIW2□2□ STANDARD SCALE RANGE TABLE |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |