| 数据搜索系统,热门电子元器件搜索 |
|
C151 数据表(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
C151 数据表(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 2 page ![]() Time Electronics 1010 DC Voltage Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2b 04/22 Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Technical Specifications Output..................................................................... 0 to 9.9999 V in 5 ranges: ................................................................................. 10 V range: 0 to 9.9999 V in 100 μV steps. ................................................................................. 1 V range: 0 to 999.99 mV in 10 μV steps. ................................................................................. 100 mV range: 0 to 99.999 mV in 1 μV steps. ................................................................................. 10 mV range: 0 to 9.9999 mV in 0.1 μV steps. ................................................................................. 1 mV range: 0 to 999.99 μV in 0.01 μV steps. Accuracy ................................................................ 10 V and 1 V ranges: ± (0.02 % of setting + 0.005 % of range). ................................................................................. 100 mV range: ± (0.05 % of setting + 0.005 % of range + 1 μV). ................................................................................. 10 mV and 1 mV ranges: ± (0.05 % of setting + 0.005 % of range + 4 μV). Output resistance.................................................. 10 V, 1 V, and 100 mV ranges: Less than 0.1 Ω (typically 0.05 Ω). ................................................................................. 10 mV and 1 mV ranges: 1 Ω. Maximum output current ...................................... 10 V, 1 V and 100 mV ranges: 25 mA. ................................................................................. 10 mV & 1 mV ranges: Up to short circuit value 30 mA, ................................................................................. Note: Loads of greater than 1 kΩ will give greater than 0.1 % error. Maximum overload................................................ The instrument can withstand continuous short circuit on the output for all ranges. ................................................................................. The 10 V, 1 V and 100 mV ranges have an automatic output current limit set at approximately 30 mA. Output voltage stability......................................... Less than 30 ppm per °C (0 to + 50 °C). Less than 5 ppm per V variation in supply voltage. ................................................................................. Less than 75 ppm per year. Less than 10 ppm per hour at constant temperature. Output polarity....................................................... Positive or negative switch selected. A centre ‘off’ position is also provided. Output noise level ................................................. 10 V, 1 V, & 100 mV ranges: Less than 10 ppm of setting ± 2 μV (0 to 10 Hz). ................................................................................. 10 mV & 1 mV ranges: Less than ± 0.05 μV (0 to 10 Hz). Reference source .................................................. Precision zener diode selected after a special ageing process for a temperature coefficient ................................................................................. better than 5 ppm per °C and stability better than 10 ppm per month, non cumulative. Power supply ......................................................... Time Electronics power unit type PU2 which is housed in the rear of the 1010. ................................................................................. The PU2 will power the 1010 direct from the mains or an internal rechargeable battery. ................................................................................. The battery is automatically charged when mains power is connected. ................................................................................. Access to the power supply is from the back of instrument. Battery level indicator ........................................... A front panel LED provides an indication of the battery condition. General Specifications Dimensions ............................................................ W 217 x H 160 x D 193 mm. Weight..................................................................... 3.3 kg. Optional extras ...................................................... Leather carry case. ................................................................................. Calibration certificates - traceable (Factory) or accredited (ISO 17025). Country of origin.................................................... UK. Ordering Information 1010......................................................................DC Voltage Calibrator 9021......................................................................... Carry case C151........................................................................ Traceable calibration certificate (Factory) C102........................................................................ Accredited calibration certificate (ISO 17025) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |