2 / 2 page ![]() www.timeelectronics.com 5025 Specifications TECHNICAL SPECIFICATIONS STANDARD FEATURES Function Range Best 1 year Specification Voltage DC 0 to ± 1050V ± 15ppm of setting Current DC 0 to ± 22A ± 80ppm of setting Voltage AC 1mV to 1050V (10Hz to 20kHz, sine-wave) ± 300ppm of setting Current AC 10µA to 22A (20Hz to 1kHz, sine-wave) ± 0.05% of setting Resistance 1Ω to 1GΩ (Fixed values, decade steps) ± 20ppm of setting Conductance 1s to 1ns (Fixed values, decade steps) ± 20ppm of setting Thermocouple Simulation -270 to 1800°C (Type J, K, R, T, S, B, E, N) ± 0.15°C 10MHz Digital Frequency/Period 0.1Hz to 10MHz / 100ns to 10s ± 20ppm of setting OPTIONS (option code in brackets) Option Range / Values Best 1 year Specification Wideband AC Voltage (9771) 20 to 200mV/300kHz. 0.2 to 2V/1MHz. 2 to 20V/100kHz ± 0.05% of setting Capacitance (9798) 1nF, 10nF, 100nF, 1µF, 10µF, 100µF ± 0.25% of setting Inductance (9798) 1mH, 1.9mH, 5mH, 10mH, 19mH, 50mH, 100mH, 190mH, 500mH, 1H, 10H ± 0.1% of setting Full Range Resistance (9787) 1Ω to 120MΩ (Variable) ± 100ppm of setting PT100 -200 to 850°C ± 0.2°C Power Calibration (9797) 22A, 1050V, 23kW, 45 to 400Hz ACV: 0.03%, DCV: 0.01% ACI: 0.1%, DCI: 0.03% Phase/Power Factor ± 90°/ 0.00 to 1.00PF ± 0.3° External Options AC Current Transformer (9790): 100A / 100kW. Clamp Meter Adaptor x50 turn (9780): 1100A / 1.1MW Oscilloscope Calibration (9770) Amplitude 0mV to 200V and 0mV to 2V 50Ω (square-wave or DC) ± 0.05% Frequency/Period 0.1Hz to 100MHz / 100ns to 10s ± 20ppm (± 0.1ppm optional) Duty Cycle 3 frequencies: 100Hz, 1kHz, 10kHz, settable from 0 to 100% Fast-Rise <850ps. Bandwidth checking up to 400MHz 2.2GHz Sweep (9769) 100MHz to 2.2GHz levelled sine-wave (0.5, 1, 1.5V pk-pk) Amplitude ± 1%, Frequency ± 20ppm GENERAL SPECIFICATIONS Warm up......................................................30 minutes to full accuracy Settling Time ...............................................Less than 5 seconds Standard Interfaces.....................................GPIB (IEEE-488), RS-232, USB Temperature Performance ..........................Operating: 5 to 40°C, Full Spec: 22°C +/- 3°C, Storage: -10°C to 50°C Operating Humidity/Altitude ....................... < 80% non condensing / Altitude: 0 to 3km. Non operating: 3km to 12km Line Power...................................................100 to 230V AC 50/60 Hz. 200W maximum Dimensions / Weight...................................W455mm, H155mm, D480mm. Weight: 16.5kg ORDERING INFORMATION Time Electronics Ltd, Unit 11 Sovereign Way, Botany Industrial Estate, Tonbridge, Kent, TN9 1RH. United Kingdom. T: +44 (0)1732 355993 F: +44 (0)1732 770312 E: mail@timeelectronics.co.uk 5025 ................................................................... Multifunction Calibrator 9798 ................Capacitance (1000pF - 100µF) / Inductance (1mH - 10H) 9774 ................................................. Simulated Resistance (10Ω - 40MΩ) 9787 ................................................ Full Range Resistance (1Ω - 120MΩ) 9771 ............................. Wideband AC Voltage (1MHz Max. 20mV - 20V ) 9797 ..........................................Power Calibration (0 - 20KW AC and DC) 9770 .................. Oscilloscope Calibration (1mV - 200V, 0.1Hz - 100MHz) 9769 ............................................Scope 2.2GHz Levelled Sine Generator 9783 ............... Oven-Controlled Frequency Reference (scope opts only) 9762 .......... Rubidium Frequency Reference (external - scope opts only) 9764 ..... Current Probe Calibration Adaptor (external - scope opts only) 5065 ................................................................. 6.5 Digit Bench Multimeter 9773 ........................................................................Optical Tacho Adaptor 9780 .............................................Clamp Meter Adaptor (1 & 50 turn coil) 9759 ...................................................Torque Wrench Calibration Adaptor 9790 ......................................................100 Amp AC Current Transformer 9760 ......................................Power Amplifier (60V AC, 90V DC - 100mA) 9766 ...............................................External Low Noise Attenuator 1000:1 9767 .................................................External Low Noise Attenuator 100:1 9085 .................................................................... Soft Carry Case for 5025 9728 .............................................................19” Universal Rack Mount Kit 9541 ..........................................................................5 piece Test Lead Set 9796 ........................................................11 piece Premium Test Lead Set C159..................................................Factory Calibration Certificate (NPL) C103..........................................UKAS Calibration Certificate (ISO 17025) C113.........................Extended UKAS Calibration Certificate (ISO 17025) 9795 ....................................................................Printer & Connectivity Kit ECFLA................EasyCal Software (see separate datasheet for options) Full specifications are available on request. Due to continuous development Time Electronics reserves the right to change specifications without prior notice. v2d 27/5/11 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |