| 数据搜索系统,热门电子元器件搜索 |
|
C137 数据表(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
C137 数据表(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 2 page ![]() Time Electronics 5030 Electrical Tester Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2c 08/22 Technical Specifications Loop Function Range / Values Resolution Accuracy Loop Impedance Resistor Values 1800, 330.0, 180.0, 33.00, 18.00, 3.300, 1.800, 0.330, 0.150, 0.050 Ω 4 digit ± 0.5 % of displayed value ± 30 mΩ Local Loop Compensation 0 to 9.999 Ω 0.001 Ω ± 0.5 % of value ± 30 mΩ Test Current 30 A max (200 ms) / 50 W max – – RCD Function Range / Values Resolution Accuracy Trip Time 10 to 2000 ms 10 ms ± 0.5 ms Current 6.000, 10.00, 30.00, 100.0, 300.0, 500.0, 1000 mA 4 digit ± 0.5 % of reading ± 1 % with x5 multiplier Current Multipliers x0.5, x1, x2, x5 – – Maximum Current 2500 mA – – Waveforms AC, DC & half wave rectified – – Phase Detection 0° or 180° – – Pre Trigger Delay 0 to 2000 ms 10 ms – Pre Trigger Threshold 0 to 100 % of nominal current 1 % – Insulation Function Range / Values Resolution Accuracy Resistance 1 MΩ to 2000 MΩ 1 MΩ 1 % of value 50 kΩ to 1990 kΩ 50 kΩ 1 % of value Test Voltage Measurement @ 0.5 mA or 1.0 mA Load 50.0 to 99.9 V DC 0.1 V 1 % of reading 100 to 1200 V DC 1 V 1 % of reading Continuity Function Range / Values Resolution Accuracy Resistance 0.1 Ω to 100.0 Ω 0.1 Ω 1 % of value + 20 mΩ 250 Ω, 500 Ω, 1.00 kΩ, 2.50 kΩ, 5.00 kΩ & 10.0 kΩ 3 digit 1 % of value Test Voltage Measurement (input resistance 10 MΩ) 0.0 to 50.0 V DC 0.01 V 0.5 % of range Test Current Measurement (between 1 Ω and 2 Ω) 0 to 400 mA DC 0.1 mA 0.5 % of range Power Dissipation 1 watt maximum – – Voltage Function Range Resolution Accuracy Line Voltage Measurement 100.0 to 260.0 V RMS 0.1 V 0.5 % of reading Line Frequency Measurement 45.00 to 65.00 Hz 0.01 Hz 0.1 % of reading General Specifications Warm up ...................................................................... 30 minutes to full accuracy. Settling time ..........................................................................Less than 5 seconds. Standard interfaces.................................................................... RS-232 and USB. Temperature performance ............................................... Operating: 10 to 35 °C, Full spec: 23 °C ± 5 °C, Storage: -10 °C to 50 °C. Operating humidity/altitude.........< 80 % non condensing / Altitude: 0 to 3 km. Non operating altitude: 3 to 12 km. Line power................................................................... 220 to 240 V AC 50 Hz. 100 to 120 V AC 60 Hz (specify on order). Power consumption 200 W maximum. Dimensions / Weight.........................W 430 x H 155 x D 255 mm / Weight: 8 kg. Supplied with ...........................User manual, RS-232 cable, USB adaptor/cable. Ordering Information 5030 ...........................................................................Electrical Tester Calibrator C201........................................................ Traceable calibration certificate (Factory) C137................................................. Accredited calibration certificate (ISO 17025) ECFLA............................... EasyCal Software (see separate datasheet for options) Due to continuous development Time Electronics reserves the right to change specifications without prior notice. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |