| 数据搜索系统,热门电子元器件搜索 |
|
C147 数据表(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
C147 数据表(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 3 page ![]() Time Electronics 5045 Oscilloscope Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Technical Specifications Specifications are for 1 year and apply between 23 °C ± 5 °C Standard features Function Range Specification (± output + floor) Resolution Amplitude DC or 1 kHz Square wave DC Signal Square Wave Signal 2 to 200 mV (1 MΩ) 0.2 to 20 V (1 MΩ) 20 to 220 V (1 MΩ) 1 to 200 mV (50 Ω) 0.2 to 2 V (50 Ω) ± 0.20 % + 10 μV ± 0.05 % + 10 μV ± 0.05 % + 10 μV ± 0.25 % + 15 μV ± 0.25 % + 15 μV ± 0.25 % + 100 μV ± 0.25 % + 1 mV ± 0.25 % + 10 mV ± 0.25 % + 200 μV ± 0.5 % + 1 mV 10 μV 1 mV 10 mV 100 μV 1 mV The square wave signal is a chopped DC voltage with defined high and low levels, accuracy applies to the top line measurement relative to ground. Calibration is performed using the DC signal. Amplitude frequency accuracy < 10 ppm. Frequency 0.1 Hz to 10 MHz 20 MHz to 100 MHz ± 0.1 ppm ± 20 ppm Fixed outputs in 1, 2, 5, 10 sequenced steps Period 10 s to 100 ns 50 ns to 10 ns ± 0.1 ppm + 30 ps ± 20 ppm + 50 ps Square wave from 0.1 Hz to 50 MHz; sinusoidal at 100 MHz. Amplitude > 0.9 Vpp into 50 Ω. Duty Cycle 0 to 100% at 100 Hz, 1 kHz, 10 kHz Derived from the period (time interval) specification 0.01 % at 100 Hz 0.1 % at 1 kHz 1 % at 10 kHz Fast Rise* 10 MHz Rise time less than 300 ps (> 400 mVpp into 50 Ω) 2.2 GHz Levelled Sine-Wave (option 9769)* Amplitude Range 0.35, 0.5, 1, 1.5 Vpp Frequency Range 50 to 199.9 MHz 200 to 499.9 MHz 500 to 999.9 MHz 1 to 2.2 GHz 1 year absolute accuracy 3 % 4 % 5.5 % 6.5 % Amplitude Range 2, 2.5, 3 Vpp Frequency Range 50 to 199.9 MHz 200 to 499.9 MHz 500 to 999.9 MHz 1 to 1.6 GHz 1 year absolute accuracy 3 % 4 % 5.5 % 6.5 % Amplitude Range 3.5 Vpp Frequency Range 50 to 199.9 MHz 200 to 499.9 MHz 500 to 999.9 MHz 1 to 1.3 GHz 1 year absolute accuracy 3 % 4 % 5.5 % 6.5 % Frequency accuracy 20 ppm, resolution 0.1 MHz. Amplitude deviation of ±5 % on 0.5, 1, 1.5, 2, 2.5, 3 and 3.5 V ranges, +5 % on 0.35 V range. The levelled sine option is calibrated at the terminal. Any external losses must be accounted for. *Accredited calibration is not available for this function/option. Note: 2.2 GHz levelled sine-wave option specifications apply to models manufactured after 2020. For models prior to this year please consult legacy specifications or contact us. External Options Rubidium reference (option 9762) Rubidium atomic clock 10 MHz frequency reference. Increases accuracy to 1 part in 1010. (Applies to 10 MHz maximum output on 5045) Current probe adaptor (option 9764) Battery powered external adaptor for checking current probes. 0.1 to 100 mA, 0.2 % accuracy. Due to continuous development Time Electronics reserves the right to change specifications without prior notice. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |