| 数据搜索系统,热门电子元器件搜索 |
|
9743 数据表(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
9743 数据表(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 3 page ![]() Time Electronics 5025E Multifunction Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com Technical Specifications (for full technical data see extended specifications sheet) Function Range / Values Best 1 year Specification Voltage DC 0 to ± 1050 V ± 40 ppm of setting Current DC 0 to ± 22 A 1100 A with clamp meter adaptor (option 9780) ± 120 ppm of setting Voltage AC 1 mV to 1050 V / 20 Hz to 20 kHz sine-wave ± 0.04 % of setting Current AC 10 μA to 22 A / 20 Hz to 1 kHz sine-wave 100 A with current transformer (option 9790) 1100 A with clamp meter adaptor (option 9780) ± 0.07 % of setting Thermocouple simulation -210 to 1820 °C. Type J, K, R, T, S, B, E, N ± 0.3 °C Digital frequency/period 0.1 Hz to 10 MHz / 100 ns to 10 s ± 20 ppm of setting Conductance 100 ms to 1 ns (decade values) ± 60 ppm of setting Decade resistance 10 Ω to 1 GΩ (decade values) ± 60 ppm of setting Simulated resistance 40 Ω to 40 kΩ (variable) ± 0.02 % of setting PT100 simulation -140 °C to 850 °C ± 0.25 °C Capacitance 10 nF, 20 nF, 50 nF, 100 nF, 1 μF ± 0.25 % of setting Option 9780: Clamp meter adaptor AC/DC Current up to 1100 A (DC, 45 to 90 Hz) ± 0.5 % Option 9770: Oscilloscope Calibration Amplitude 2 mV to 200 V and 1 mV to 2 V 50 Ω (Square-wave or DC) ± 0.05 % Frequency/Period 0.1 Hz to 100 MHz / 10 ns to 10 s (fixed values 1, 2, 5 sequence) ± 20 ppm Duty cycle 3 frequencies: 100 Hz, 1 kHz, 10 kHz, settable from 0 to 100 % – Fast-rise < 400 ps. Bandwidth checking up to 400 MHz – Option 9783: Frequency reference 0.1 Hz to 10 MHz enhanced frequency accuracy reference ± 0.1 ppm (enhanced accuracy for timer/counters) Option 9769: 2.2 GHz Sweep 50 MHz to 2.2 GHz levelled sine-wave (0.5, 1, 1.5 V pk-pk) Amplitude ± 1 %, Frequency ± 20 ppm Option 9797: Power Calibration Power 22 A, 1050 V, 23 kW, 45 to 400 Hz ACV: 0.03 %, DCV: 0.01 %. ACI: 0.1%, DCI: 0.03 % Phase / Power factor ± 90° / 0.00 to 1.00 PF ± 0.3° Option 9702: Enhanced Performance Pack (added values/types shown in bold where applicable) Full range resistance 1 Ω to 120 MΩ (variable) ± 100 ppm of setting RTD Simulation –180 to 850 °C. Type Pt100, Pt200, Pt500, Pt1000 ± 0.03 °C Extended thermocouple simulation –210 to 2315 °C. Type J, K, R, T, S, B, E, N, C, L, U ± 0.05 °C Extended capacitance 1nF, 10nF, 20nF, 50nF, 100nF, 200nF, 500nF, 1μF, 10μF, 20μF, 50μF, 100μF ± 0.2 % of setting Extended AC voltage frequency 1 mV to 200 mV/300 kHz, 200 mV to 2 V/1 MHz ± 0.05 % of setting External Options External Adaptors/Instruments 9780: Clamp meter adaptor (1 and 50 turn coil) • 9773: Optical tacho adaptor • 9790: 100 Amp AC current transformer 9760: Power amplifier (60 V AC, 90 V DC, 100 mA) • 9762: Rubidium high stability frequency reference 9764: Current probe calibration adaptor • 9766: Low noise attenuator (1000:1) • 9767: Low noise attenuator (100:1) Accessories and Calibration Certificates 9085: Soft carry case • 9059: Hard transit case • 9728: 19 " Universal rack mount kit 9796: Premium test lead set • C159: Traceable calibration certificate • C103: Accredited calibration certificate EasyCal Software ECFLA: EasyCal full license • 9777: Bar code reader • 9779: Job and address label printer EC2FL/EC2WL: Additional user licenses • EAD: EasyAdmin add-on • EWC: WebCerts • CREP: Crystal Reports software General Specifications Supplied accessories ........................Basic test lead set • PC virtual control software • RS-232 cable • RS-232 to USB adaptor • User manual. Warm up ............................................30 minutes to full accuracy. Temperature performance .................Operating: 5 to 45 °C. Full Spec: 23 °C ± 5 °C. Storage: –10 to 50 °C. Operating humidity / Altitude ............< 80 % non condensing. Altitude: 0 to 3 km. Non operating: 3 to 12 km. Line power........................................100 to 230 V AC 50/60 Hz. 200 W maximum. Interfaces..........................................RS-232 and USB. Dimensions / Weight .......................W 455 x H 155 x D 480 mm. Weight: 16.5 kg. Due to continuous development Time Electronics reserves the right to change specifications without prior notice. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |