5 / 22 page ![]() Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. E (07/2024) The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data at 150mA (T j=Tsp=25°C) Part Number1,6 Nominal CCT2 (K) CRI3, 5 ( Typical) Nominal Drive Current (mA) Forward Voltage4, 5 (V) Typical Pulsed Flux (lm)4, 5 Typical Power (W) Typical Efficacy (lm/W) Min Typical Max Min Typical Max BXEN-27S-11M-3C-00-0-0 2700 97 150 2.90 3.13 3.30 45 51 55 0.5 109 BXEN-30S-11M-3C-00-0-0 3000 97 150 2.90 3.13 3.30 45 53 60 0.5 113 BXEN-35S-11M-3C-00-0-0 3500 97 150 2.90 3.13 3.30 45 53 60 0.5 113 BXEN-40S-11M-3C-00-0-0 4000 97 150 2.90 3.13 3.30 50 56 65 0.5 119 BXEN-50S-11M-3C-00-0-0 5000 96.5 150 2.90 3.13 3.30 50 56 65 0.5 119 BXEN-57S-11M-3C-00-0-0 5700 96 150 2.90 3.13 3.30 50 56 65 0.5 119 BXEN-65S-11M-3C-00-0-0 6500 95.5 150 2.90 3.13 3.30 50 56 65 0.5 119 Table 2: Selection Guide, Pulsed Test Performance at 150mA (T sp = 55°C) 7,8 Part Number1,6 Nominal CCT2 (K) CRI3, 5 ( Typical) Nominal Drive Current (mA) Forward Voltage5 (V) Typical Pulsed Flux (lm)5 Typical Power (W) Typical Efficacy (lm/W) Min Typical Max Min Typical Max BXEN-27S-11M-3C-00-0-0 2700 97 150 2.87 3.10 3.27 42.9 48.7 52.5 0.5 105 BXEN-30S-11M-3C-00-0-0 3000 97 150 2.87 3.10 3.27 42.9 50.6 57.2 0.5 109 BXEN-35S-11M-3C-00-0-0 3500 97 150 2.87 3.10 3.27 42.9 50.6 57.2 0.5 109 BXEN-40S-11M-3C-00-0-0 4000 97 150 2.87 3.10 3.27 47.7 53.4 62.0 0.5 115 BXEN-50S-11M-3C-00-0-0 5000 97 150 2.87 3.10 3.27 47.7 53.4 62.0 0.5 115 BXEN-57S-11M-3C-00-0-0 5700 97 150 2.87 3.10 3.27 47.7 53.4 62.0 0.5 115 BXEN-65S-11M-3C-00-0-0 6500 97 150 2.87 3.10 3.27 47.7 53.4 62.0 0.5 115 Notes for Tables 1 & 2: 1. The last 6 characters (including hyphens ‘-’) refer to flux bins, forward voltage bins, and color bin options, respectively. “00-0-0” denotes the full distribution of flux, forward voltage, and color bin. Example: BXEN-27S-11M-3C-00-0-0 refers to the full distribution of flux, forward voltage, and color within a 2700K 6-step ANSI standard chromaticity region with a minimum of 95.5 CRI, 1x1 die configuration, mid power, 3.13V typical forward voltage. 2. Product CCT is hot targeted at T sp = 55°C. Nominal CCT as defined by ANSI C78.377-2011. 3. Listed CRIs are typical values . 4. Products tested under pulsed condition (10ms pulse width) at nominal drive current 5. Bridgelux maintains a ±7.5% tolerance on luminous flux measurements, ±0.15V tolerance on forward voltage measurements, and ±3 tolerance on CRI measurements for the SMD 2835. 6. Refer to Table 6 and Table 7 for Bridgelux SMD 2835 Luminous Flux Binning and Forward Voltage Binning information. 7. Typical pulsed test performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under pulsed current with LED emitter mounted onto a heat sink with thermal interface material and the solder point temperature maintained at 55°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and the exposed environment to which the product is subjected. Product Selection Guide 3 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |