| 数据搜索系统,热门电子元器件搜索 |
|
AS3689 数据表(PDF) 57 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3689 数据表(HTML) 57 Page - ams-OSRAM AG |
|
57 / 72 page ![]() AS3689 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (mlg, ptr) Revision 1.0.2 / 20070115 55 - 70 The reset levels control the state of all registers. As long as VBAT and VDD_GPIO are below their reset thresholds, the register contents are set to default. Access by serial interface is possible once the reset thresholds are exceeded. Table 24 – Reset Levels Symbol Parameter Min Typ Max Unit Note VPOR_VBAT Overall Power-On Reset 2.0 V Monitor voltage on V2_5; power-on reset for all internal functions. VGPIO_Vdd_TH_RISI NG Reset Level for VDD_GPIO Rising 1.3 V Monitor voltage on pin VDD_GPIO; rising level. VGPIO_vdd_TH_FAL LING Reset Level for VDD_GPIO Falling 1.0 V Monitor voltage on pin VDD_GPIO; falling level. 7.9 Temperature Supervision An integrated temperature sensor provides over-temperature protection for the AS3689. This sensor generates a flag if the device temperature reaches the overtemperature threshold of 140º. The threshold has a hysteresis to prevent oscillation effects. If the device temperature exceeds the 140º threshold all current sources, the charge pump, the ldo and the dcdc converter is disabled and the ov_temp flag is set. After decreasing the temperature by 5º (typically) operation is resumed. The ov_temp flag can only be reset by first writing a 1 and then a 0 to the (bit rst_ov_temp ). Bit ov_temp_on = 1 activates temperature supervision. Table 25 – Overtemperature Detection Symbol Parameter Min Typ Max Unit Note T140 ov_temp Rising Threshold 140 º C Thyst ov_temp Hystersis 5 º C 7.9.1 Temperature Supervision Registers Addr: 29h Overtemp Control This register reads and resets the overtemperature flag. Bit Bit Name Default Access Description 0 ov_temp_on 1 W Activates/deactivates device temperature supervision. Default: Off – all other bits are only valid if this bit is set to 1. 0 = Temperature supervision is disabled. No reset will be generated if the device temperature exceeds 140ºC. 1 = Temperature supervision is enabled. 1 ov_temp N/A R 1 = Indicates that the overtemperature threshold has been reached; this flag is not cleared by an overtemperature reset. It has to be cleared using bit rst_ov_temp . 2 rst_ov_temp 0 R/W The ov_temp flag is cleared by first setting this bit to 1, and then setting this bit to 0. 7:4 N/A |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |