13 / 18 page ![]() DIO70040 Version 1.3, Aug 2025 www.dioo.com © 2025 Dioo Microcircuits Co., Ltd. Jiangsu 9 9.5. Thermal protection Thermal protection prevents damage to the IC when heavy overload or short circuit conditions are present for extended periods of time. The conditions force the DIO70040 into constant current mode, and under short circuit conditions, the voltage across the switch is equal to the input voltage. The increased dissipation causes the junction temperature to rise to high levels. The protection circuit senses the junction temperature of the switch and shuts it off. Hysteresis is built into the thermal sense circuit, and after the device has cooled approximately 20 degrees, the switch turns back on. The switch continues to cycle in this way until the overload or input power is removed. 9.6. Reverse-voltage protection The reverse-voltage protection feature turns off the P-channel MOSFET whenever the output voltage exceeds the input voltage by 175 mV (typ). A reverse current of (VOUT - VIN) / RDS(ON) will be present when this occurs. This prevents damage to devices on the input side of the DIO70040 by preventing significant current from sinking into the input capacitance. The DIO70040 devices allow the P-channel MOSFET to turn on once the output voltage goes bellow the input voltage. 9.7. FLG output Error flag is an open-drain output of a N-channel MOSFET. If current limiting or short circuit occurs, FLG is pulled low after a delay of 8 ms (typ), and if no current limiting or short circuit occurs, FLG is pulled high after a delay of 8 ms (typ). If reverse-voltage protection occurs, FLG is pulled low after a delay of 4 ms (typ), and if no reverse-voltage protection occurs, FLG is pulled high after a delay of 4 ms (typ). If overtemperature protection occurs, FLG is pulled low immediately, and if no overtemperature protection occurs, FLG is pulled high after a delay of 8 ms (typ). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |