24 / 30 page ![]() A22 24 Application Mounting to the Panel Panel Hole Dimensions • Panel hole dimensions are given below. • Recommended panel thickness: 1 to 5 mm. • For 25-dia. holes, always use 25-dia. Rings. (Since the cutout dimensions are large, IP65 cannot be guaranteed unless 25-dia. Rings are used.) • If outer surface treatment such as coating is performed for the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. Matrix Installation 1. The following panel hole dimensions apply when Switch Unit and the Standard-size Legend Plate Frame and Lock Ring are mounted, and lead wires are connected directly to the Switch Block. 2. The following panel hole dimensions apply when the Large-size Legend Plate Frame is mounted, and when crimp terminals are connected to the Switch Block terminals. For 1. above: For 2. above: Note: 1. The above dimensions are the minimum dimensions for when the wires described under Applicable Wire Size on page 23 are used. If a different wires are used, the wiring dimensions may be different so determine an appropriate pitch before setup. 2. With pushbuttons of external dimensions greater than 30 mm, set the pitch according to the dimensions. (When using matrix installation for the A22-M @, mount with a pitch of 40 mm instead of 30 mm in the diagram above.) Mounting the Operation Unit on the Panel • Insert the Operation Unit (Pushbutton, etc.) from the front surface of the panel, insert the Lock Ring and the mounting nut from the terminal side, then tighten the nut. Before tightening, check that the rubber washer is present between the Pushbutton Unit and the panel. • When using a Legend Plate Frame, put one rubber washer each between the Legend Plate Frame and the panel and between the Operation Unit and the Legend Plate Frame. (One rubber washer will be provided when one Legend Plate Frame is ordered.) • Align the Lock Ring with the groove in the casing, then insert the Lock Ring so that its edge is located on the panel side. 22.3 +0.4 0 +0.2 0 22.3 25 dia. 22 dia. +0.4 0 25 +0.5 0 3.2 0.8R max. Not Using a Lock Ring Using a Lock Ring Switch Blocks A A22-10, A22-10S A22-01, A22-01S 45 mm min. A22-20, A22-20S, A22-02 A22-02S, A22-11, A22-11S 55 mm min. Type of crimp terminal Switch Blocks B Bare crimp terminals A22-10, A22-10S A22-01, A22-01S 51 mm min. A22-20, A22-20S, A22-02 A22-02S, A22-11, A22-11S 61 mm min. Crimp terminals with insulating sheath A22-10, A22-10S A22-01, A22-01S 60 mm min. A22-20, A22-20S, A22-02 A22-02S, A22-11, A22-11S 70 mm min. 30 A 30 B Pitches A and B between the centers of the mounting holes are as follows: |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |