30 / 50 page  4/16 4 Control specifications 4-32 VDC 18-36 VAC/DC 90-280VAC/DC Drop-out voltage 1V 1V 10V Max. regulated current (mA) 14 20 8.5 Turn-on time (ms) (zero voltage relay) 8.33 (60Hz) - 10 (50Hz) 20 20 Turn-on time (ms) (instantaneous relay) 0.1 0.1 0.1 Turn-off time (ms) 8.33 (60Hz) - 10 (50Hz) 30 30 Output specifications 24-280 VAC 48-660 VAC Peak voltage not rep. (Vp) 600 1200 Off-state leakage (@ Vmax and T=25°C) 2.5 - 4.25 2.75 - 4.75 Max. current (A) 10 25 50 75 100 125 Minimum current (mA) 100 100 100 100 100 100 Max. non-rep. 1 s surge (T=25°C) (A) 80 150 235 300 360 510 Max. non-rep. 1-cycle surge (T=25°C) (A) 300 500 780 1000 1200 1700 |2t (50Hz-60Hz) (A2S) 375-450 1041-1250 2535-3042 4166-5000 6000-7000 12041-14450 Voltage drop at Imax (T=25°C) (V) 1.4 1.4 1.35 1.3 1.3 1.25 Static dV/dt (V/µs) 500 500 500 500 500 500 Thermal resistance Junction/to casing (°C/W) 0.4 0.4 0.25 0.155 0.155 0.15 GN. 10 AMP SSR (1200 & 600 V) 10,0 8,0 6,0 4,0 2,0 0,0 20 25 30 35 40 45 50 55 60 65 70 75 80 3,0 °C/W 7,0 °C/W 5,0 °C/W GN. 25 AMP SSR (1200 & 600 V) 25,0 20,0 15,0 10,0 5,0 0,0 20 25 30 35 40 45 50 55 60 65 70 75 80 1,0 °C/W 1,7 °C/W 1,5 °C/W 3,0 °CW 2,0 °CW GN. 50 AMP SSR (1200 & 600 V) 50,0 40,0 30,0 20,0 10,0 0,0 20 25 30 35 40 45 50 55 60 65 70 75 80 0,5 °C/W 1,0 °C/W 0,7 °C/W 2,0 °C/W 1,5 °C/W GN. 75 AMP SSR (1200 & 600 V) 75,0 50,0 25,0 0,0 20 25 30 35 40 45 50 55 60 65 70 75 80 0,4 °C/W 0,7 °C/W 0,5 °C/W 1,5 °C/W 1 °C/W GN. 100 AMP SSR (1200 & 600 V) 100,0 90,0 80,0 70,0 0,0 10,0 20,0 30,0 40,0 50,0 60,0 10 20 30 40 50 60 70 80 0 0,25 °C/W 0,5 °C/W 0,4 °C/W 1,0 °C/W 0,7 °C/W GN. 125 AMP SSR (1200 & 600 V) 125,0 100,0 75,0 0,0 25,0 50,0 10 20 30 40 50 60 70 80 0 0,25 °C/W 0,5 °C/W 0,4 °C/W 1,0 °C/W 0,7 °C/W Ambient temperature (°C) HEATSINK Ambient temperature (°C) HEATSINK Ambient temperature (°C) HEATSINK Ambient temperature (°C) HEATSINK Ambient temperature (°C) HEATSINK Ambient temperature (°C) HEATSINK Thermal curves |
|