| 数据搜索系统,热门电子元器件搜索 |
|
E3H2-R2C4M-M1-N 数据表(PDF) 4 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E3H2-R2C4M-M1-N 数据表(HTML) 4 Page - Omron Electronics LLC |
|
4 / 13 page ![]() 4 Miniature Photoelectric Sensors Operation Sensitivity adjustment E3H2-T4 The emitter of the E3H2-T4 allows an adjustment of the emitted amount of light by turning the potentiometer. Turn the potentiom- eter clockwise for increasing the amount of emitted light and counter-clockwise for decreasing the amount of emitted light. E3H2-R2 a) standard mode To teach the retro-reflective model E3H2-R, place the sensor with the lens facing the reflector. Press the teach button for 2- 5 seconds. For remote teach connect the white wire (Pin 2) for 2-5 seconds to common (-). The threshold is now set to 50% of the received light level. b) high sensitivity mode (e.g. for semi-transparent models) To teach the retro-reflective model E3H2-R in high sensitivity mode, place the sensor with the lens facing the reflector. Press the teach button for >8 seconds. For remote teach con- nect the white wire (Pin 2) for >8 seconds to common (-). The threshold is now set just below the received light level. If the teaching was successful the LED should no longer be flash- ing and a state change occurs when the light is interrupted. E3H2-DS30 a) standard mode To teach the diffuse-reflective model E3H2-DS30, place the object in front of the sensor at the required sensing distance. Press the teach button for 2-5 seconds. For remote teach connect the white wire (Pin 2) for 2-5 seconds to common (-). The threshold is now set to 50% of the received light level. When the object is removed, a state change at the sensor should occur. If this is not the case the high sensitivity mode may be required. b) high sensitivity mode To teach the diffuse-reflective model E3H2-DS30 in high sen- sitivity mode, place the object in front of the sensor at the required sensing distance. Press the teach button for >8 seconds. For remote teach connect the white wire (Pin 2) for >8 seconds to common (-). The threshold is now set just below the received light level. When the object is removed, a state change at the sensor should occur and the LED should no longer be flashing. For E3H2-T2 and E3H2-DS10 the sensitivity setting is fixed. Operation mode selection The light-on / dark-on operation mode can be selected by wire (except for E3H2-T2). The white wire (Pin 2) can be connected to plus (+), common (-) or left open (not connected) for the default setting. a) E3H2-T4 Receiver Default setting (wire left open):DARK-ON Connected to plus (+): LIGHT-ON Connected to common (-): DARK-ON b) E3H2-R2 Default setting (wire left open):DARK-ON Connected to plus (+): LIGHT-ON Connected to common (-): TEACH*1 c) E3H2-DS30 Default setting (wire left open):LIGHT-ON Connected to plus (+): DARK-ON Connected to common (-): TEACH*1 d) E3H2-DS10 Default setting (wire left open):LIGHT-ON Connected to plus (+): DARK-ON Connected to common (-): LIGHT-ON For E3H2-T2 the operation mode is fixed and models with light- on and dark-on operation are available. *1 In case the remote teach operation is required when the white wire is con- nected to plus (+), add a 2.2 k resistor between the white wire and (+) to avoid a short circuit. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |