| 数据搜索系统,热门电子元器件搜索 |
|
E5DC-RX2DSM-002 数据表(PDF) 35 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5DC-RX2DSM-002 数据表(HTML) 35 Page - Omron Electronics LLC |
|
35 / 112 page ![]() E5EC/E5AC 35 Model Number Legend and Standard Models Model Number Legend ●Models with Screw Terminals E5EC- @@ 4 @ 5M -@@@ (Example: E5EC-RX4A5M-000) −− − − − − −−− AB C D E F E5AC- @@ 4 @ 5M -@@@ (Example: E5AC-RX4A5M-000) −− − − − − −−− AB C D E F *1. The options that can be selected depend on the type of control output. *2. The control output cannot be used as a transfer output. *3. A model with four auxiliary outputs must be selected. Heating and Cooling Control l Using Heating and Cooling Control A Control Output Assignment If there is no control output 2, an auxiliary output is used as the cooling control output. If there is a control output 2, the two control outputs are used for heating and cooling. (It does not matter which output is used for heating and which output is used for cooling.) B Control If PID control is used, you can set PID control separately for heating and cooling. This allows you to handle control systems with different heating and cooling response characteristics. Model A B C D E F Meaning Control outputs 1 and 2 No. of auxil- iary out- puts Power supply voltage Terminal type Input type Options E5EC 48 × 96 mm E5AC 96 × 96 mm Control output 1 Control output 2 RX Relay output None QX Voltage output (for driving SSR) None *2 CX Linear current output None QQ Voltage output (for driving SSR) Voltage output (for driving SSR) QR Voltage output (for driving SSR) Relay output RR Relay output Relay output *2 CC Linear current output Linear current out- put *2 CQ Linear current output Voltage output (for driving SSR) PR Position-proportional relay output Position-proportion- al relay output *3 4 4 (auxiliary outputs 1 and 2 with same common and auxilia- ry outputs 3 and 4 with same common) A 100 to 240 VAC D 24 VAC/DC 5 Screw terminals (with cover) Control outputs 1 and 2 M Universal input Option selection conditions *1 For RX, QX, QQ, QR, RR, or CQ For CX or CC For PR HB alarm and HS alarm Communications Event inputs Remote SP Input Transfer output Selectable Selectable Selectable 000 --- --- --- --- --- Selectable Selectable 004 --- RS-485 2 --- --- Selectable 005 --- --- 4 --- --- Selectable 009 2 (for 3-phase heaters) RS-485 2 --- --- Selectable 010 1 --- 4 --- --- Selectable 011 1 --- 6 Provided. Provided. Selectable 013 --- --- 6 Provided. Provided. Selectable Selectable 014 --- RS-485 4 Provided. Provided. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |