| 数据搜索系统,热门电子元器件搜索 |
|
E5DC-RX2ASM-017 数据表(PDF) 31 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5DC-RX2ASM-017 数据表(HTML) 31 Page - Omron Electronics LLC |
|
31 / 138 page ![]() E5CC/E5CC-B/E5CC-U 31 E5CC-B (Push-In Plus Terminal Blocks) Note: 1. The application of the terminals depends on the model. 2. Do not wire the terminals that are shown with a gray background. 3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less. If the cable length exceeds 30 m, compliance with EMC standards will not be possible. 4. Refer to Wiring Precautions for E5 @C-B (Controllers with Push-In Plus Terminal Blocks) on page 133 for wire specifications and wiring methods. 5. Common terminals are indicated with asterisks ( *). You can use the input power supply and communications common terminals for crossover wiring. Do not exceed the maximum number of Temperature Controllers given below if you use crossover wiring for the input power supply. 100 to 240 VAC Controllers: 16 max. 24 VAC/VDC Controllers: 8 max. 6. Due to UL Listing requirements, use the E54-CT1L or E54-CT3L Current Transformer with the factory wiring (internal wiring). Use a UL category XOBA or XOBA7 current transformer that is UL Listed for field wiring (external wiring) and not the factory wiring (internal wiring). 23 19 22 1 2 17 18 3 15 24 16 6 8 9 14 21 5 13 20 4 12 11 10 7 8 6 7 8 7 88 Pt A B B + - mA - + 7 6 V - 7 V + 6 TC 6 I 17 18 19 20 21 22 23 24 EV2 EV1 (-) EV2 EV1 EV4 EV3 CT1 CT1 B(+) A(-) RS-485 B(+) A(-) RS-485 17 18 19 20 21 22 23 24 17 18 19 20 21 22 23 24 17 18 19 20 21 22 23 24 13 14 15 16 9 10 11 12 * * * 13 14 15 16 * * * * * * * * * (no polarity) 100 to 240 VAC 24 VAC/DC Auxiliary output 2 Auxiliary output 1 004 Communications (RS-485), and Event Inputs 3 and 4 006 Event Inputs 1 and 2, and Transfer Output 001 Event Inputs 1 and 2, and CT1 002 Communications (RS-485), CT1 (2) Auxiliary Outputs (3) Input Power Supply (5) Sensor (Temperature/Analog) Input (6) Options Relay outputs outputs: 250 VAC, 2 A (resistive load) Auxiliary outputs 1, 2 (-) (-) (-) (-) (-) Use no-voltage inputs for the event inputs. The polarity for non-contact inputs is given in parentheses. + + - V I Transfer Output Models with 1 Relay Output (1) Control output 1 Models with 1 Voltage Output (for Driving SSR) OUT1 R 1 2 RX 1 2 OUT1 Q QX + − Models with 1 Linear Current Output 1 2 OUT1 C CX + − The E5CC is set for a K-type thermocouple (input type = 5) by default. An input error ( s.err) will occur if the input type setting does not agree with the temperature sensor. Check the input type. E5CC- @@ 2 @ B M - @@@ (1) (2) (3) (4) (5) (6) ↑ Terminal type Control output 1 Relay output 250 VAC, 3A (resistive load) Voltage output (for driving SSR) 12 VDC, 21 mA 13 14 15 16 To another E5 @C Wiring Example: |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |