| 数据搜索系统,热门电子元器件搜索 |
|
G6W-1F-R 数据表(PDF) 3 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
G6W-1F-R 数据表(HTML) 3 Page - Omron Electronics LLC |
|
3 / 8 page ![]() 3 G6W G6W ■ Characteristics Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. 2. Values in parentheses are actual values. 3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking the dielectric strength. 4. The above values are initial values. Engineering Data Classification Single-side Stable Single-winding Latching Double-winding Latching Item Model G6W-1F, G6W-1P G6WU-1F, G6WU-1P G6WK-1F, G6WK-1P Contact resistance (See note 1.) 100 m Ω max. Operate (set) time (See note 2.) 10 ms max. (Approx. 3.5 ms) 10 ms max. (Approx. 2.5 ms) Release (reset) time (See note 2.) 10 ms max. (Approx. 2.5 ms) Minimum set/reset signal width —— 12 ms Insulation resistance (See note 3.) 1,000 M Ω min. (at 500 VDC) Dielectric strength Coil and contacts 1,000 VAC, 50/60 Hz for 1 min Coil and ground, contacts and ground 500 VAC, 50/60 Hz for 1 min Contacts of same polarity 500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction 10 to 55 Hz, 1.5-mm double amplitude Malfunction 10 to 55 Hz, 2-mm double amplitude Shock resistance Destruction 1,000 m/s2 Malfunction 500 m/s2 Endurance Mechanical 1,000,000 operations min. (at 36,000 operations/hour) Electrical 300,000 operations min. (with a rated load at 1,800 operations/hour) Ambient temperature Operating: −40ºC to 70ºC (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 3 g −40 −20 250 200 150 100 50 0 0 20 40 60 80 100 Ambient temperature (˚C) Max. estimated value −60 −40 100 90 80 70 60 50 40 30 20 10 0 0 −20 20 40 60 80 100 max. avg. max. min. min. min. avg. Ambient temperature (˚C) Must set voltage Must reset voltage Z Z' Y Y' X X' 200 400 600 800 1,000 1,000 1,000 1,000 1,000 800 600 400 200 1,000 Shock direction X X' Energized Z Z' Y Y' Unit: m/s2 Sample: G6WK-1P 4.5VDC Number of Relays: 10 Not energized Ambient Temperature vs. Maximum Voltage Ambient Temperature vs. Must Set or Must Reset Voltage Shock Malfunction Note: "Maximum voltage" is the maximum voltage that can be applied to the Relay coil. Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |