| 数据搜索系统,热门电子元器件搜索 |
|
RUSB2AC1MB 数据表(PDF) 1 Page - StarTech.com Ltd. |
|
|
|||||||||||||||||||||||||||||
RUSB2AC1MB 数据表(HTML) 1 Page - StarTech.com Ltd. |
|
1 / 3 page ![]() TB-9112 Page 1 of 3 © 2021 DESCO INDUSTRIES INC Employee Owned SCS - 926 JR Industrial Drive, Sanford, NC 27332 East: (919) 718-0000 | West: (909) 627-9634 • Website: StaticControl.com June 2021 Description The SCS Common Point Ground Monitor confirms the integrity of the resistance path from the common ground point to electrical ground. It is designed in accordance with ESD TR 12-01 to “monitoring equipment ground connections.” When the Common Point Ground Monitor is plugged into an electrical receptacle, its green LEDs illuminate when both the power outlet's wiring is correct and the path-to-equipment ground via the equipment grounding conductor is intact. The monitor provides 12 verified ground points when in a PASS condition. The monitor's red LEDs illuminate and audible buzzer sounds when either the outlet’s wiring is incorrect or the path-to-equipment ground is defective. Mounting tabs make it suitable to install in workbench or equipment settings. The outlet ground line is tested by measuring voltage between it and the neutral line. It is normal to have a few volts of AC induced on the neutral line. If the Common Point Ground Monitor measures only a few volts, the ground line to neutral impedance is low and the ground line would make a suitable ESD ground point. If the monitor measures more than just a few volts between ground and neutral, this indicates either that they are not referenced to each other or that the outlet and associated wiring should be checked for loose connections. In this case, the Common Point Ground Monitor will sound a warning alarm and display a red FAIL indication and should not be used for an ESD grounding point until corrected. Use the Common Point Ground Monitor to fulfill the ANSI/ESD S6.1 section 6.3.1 requirement. “The hot, neutral and equipment grounding conductor shall be verified to be in the proper wiring orientation in accordance with the National Electric Code (NFPA 70®).” The Common Point Ground Monitor is available as the following item numbers: Item Description 770048 Common Point Ground Monitor, with North America Power Cord 770049 Common Point Ground Monitor, with UK Power Cord Packaging 1 Common Point Ground Monitor 6 Socket Head Screws, 10-32 x 1/4" 6 Split Washers, #10 2 Pan-Head Screws, #6 x 3/8" 1 Dual Lock Fastener Set, 2" Length 1 Hex Key, 5/32" 1 Power Cord, 6' Length 1 Certificate of Calibration Common Point Ground Monitor Installation, Operation and Maintenance Made in the United States of America USER GUIDE TB-9112 Figure 1. SCS Common Point Ground Monitor |
类似零件编号 - RUSB2AC1MB |
|
类似说明 - RUSB2AC1MB |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |