  B40921 Datasheet HTML 1Page - EPCOS B40921 Datasheet HTML 2Page - EPCOS B40921 Datasheet HTML 3Page - EPCOS B40921 Datasheet HTML 4Page - EPCOS B40921 Datasheet HTML 5Page - EPCOS B40921 Datasheet HTML 6Page - EPCOS B40921 Datasheet HTML 7Page - EPCOS B40921 Datasheet HTML 8Page - EPCOS B40921 Datasheet HTML 9Page - EPCOS Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 15 page
background image
3
7/23
Please read Cautions and warnings and
Important notes at the end of this document.
Hybrid polymer aluminum electrolytic capacitors
B40921
Very compact, very high ripple current – 125 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
25 ... 35 V DC
1.15
V
R
Rated capacitance CR
Capacitance tolerance
390 ... 750 µF
20% ^
= M
Dissipation factor tan
(20 °C, 120 Hz)
VR (V DC)
25
35
tan
 (max.)
0.14
0.12
Leakage current Ileak
(20 °C, 2 min)
or 3 µA, whichever is greater
Useful life1)
125 °C; VR; IAC,R
1) Refer to chapter "General technical information, 5 Useful life" on how to interpret useful life.
Requirements:
> 4000 h
|
C/C|
 30% of initial value
ESR
 2 times initial specified limit2)
2) ESRmax at 100 kHz, 20 °C
Ileak
 initial specified limit
Voltage endurance test
125 °C; VR
1000 h
Post test requirements:
|
C/C|
 15% of initial value
tan
 1.5 times initial specified limit
Ileak
 initial specified limit
Shelf life3)
125 °C, 0 V
3) Before the measurement, the capacitor shall be preconditioned by the application of the rated voltage for 1 hour.
The voltage shall be applied to the capacitor through a resistor, the value of which shall be approximately 100
.
1000 h
Requirements:
|
C/C|
 30% of initial value
tan
 2 times initial specified limit
Ileak
 initial specified limit
Biased humidity test
85 °C, 85% RH, VR
2000 h
Requirements:
|
C/C|
 30% of initial value
tan
 2 times initial specified limit
Ileak
 initial specified limit
IEC climatic category
To IEC 60068-1:2013: 40/125/56
(-40 °C/+125 °C/56 days damp heat test)
Reference standard
AEC-Q200 REV D4)
4) Refer to chapter "General technical information, 2 Standards and specifications" for further details.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com