| 数据搜索系统,热门电子元器件搜索 |
|
FL2/12 数据表(PDF) 2 Page - BLOCK Transformatoren-Elektronik GmbH |
|
|
|||||||||||||||||||||||||||||
FL2/12 数据表(HTML) 2 Page - BLOCK Transformatoren-Elektronik GmbH |
|
2 / 4 page ![]() Low profile transformer FL General Data Rated input voltage 2 x 115 Vac Rated output voltage 2 x 5 - 2 x 24 Vac Rated power 2 - 52 VA Insulation class E Maximum ambient temperature 40 °C Efficiency up to 81 % Degree of protection IP 00 Advantages Minimum size at high output Low height Dual input voltage for series or parallel connection Dual output voltage for series or parallel connection Permanent corrosion protection, high insulation value and maximum electrical reliability thanks to XtraDenseFill resin encapsulation Self-extinguishing potting material Applications As a mains transformer for adjustment of the voltage and simple electrical isolation. As an isolating transformer for the safe electrical isolation of the input and output sides. The transformer may be used to set up protective separation as a protective measure in accordance with VDE 0100. As a safety isolating transformer for the safe electrical isolation of the input and output sides. The transformer is suitable for creating SELV and PELV circuits because of the limit on the output voltage. Sample application Standards / 2 " Z Approvals W J w Z Mains transformer to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66 Isolating transformer to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, UL 5085-1/-2, CSA 22.2 No.66 Safety isolating transformer to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66 ENEC 10 (VDE), UL 5085-1/-2, CSA 22.2 No.66 Low profile transformer FL Typ FL 2/.. FL 4/.. FL 6/.. FL 8/.. FL 10/.. FL 14/.. Input Rated input voltage 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz Output Rated output voltage: Order no. 2x5 Vac: FL 2/5 2x6 Vac: FL 2/6 2x8 Vac: FL 2/8 2x9 Vac: FL 2/9 2x12 Vac: FL 2/12 2x15 Vac: FL 2/15 2x24 Vac: FL 2/24* 2x6 Vac: FL 4/6 2x8 Vac: FL 4/8 2x9 Vac: FL 4/9 2x12 Vac: FL 4/12 2x15 Vac: FL 4/15 2x18 Vac: FL 4/18 2x24 Vac: FL 4/24* 2x5 Vac: FL 6/5 2x6 Vac: FL 6/6 2x8 Vac: FL 6/8 2x9 Vac: FL 6/9 2x12 Vac: FL 6/12 2x15 Vac: FL 6/15 2x18 Vac: FL 6/18 2x24 Vac: FL 6/24* 2x6 Vac: FL 8/6 2x8 Vac: FL 8/8 2x9 Vac: FL 8/9 2x12 Vac: FL 8/12 2x15 Vac: FL 8/15 2x18 Vac: FL 8/18 2x24 Vac: FL 8/24* 2x5 Vac: FL 10/5 2x6 Vac: FL 10/6 2x8 Vac: FL 10/8 2x9 Vac: FL 10/9 2x12 Vac: FL 10/12 2x15 Vac: FL 10/15 2x18 Vac: FL 10/18 2x24 Vac: FL 10/24* 2x5 Vac: FL 14/5 2x6 Vac: FL 14/6 2x8 Vac: FL 14/8 2x9 Vac: FL 14/9 2x12 Vac: FL 14/12 2x15 Vac: FL 14/15 2x18 Vac: FL 14/18 2x24 Vac: FL 14/24* Rated Power 2 VA 4 VA 6 VA 8 VA 10 VA 14 VA No-load voltage (app. x factor) 1.35 1.35 1.35 1.22 1.32 1.28 No-load loss (typ.) 0.60 W 0.90 W 1.20 W 1.30 W 1.10 W 1.20 W Efficiency 66.0 % 66.0 % 69.0 % 76.0 % 72.0 % 74.0 % Standards Classification Safety isolating transformer *Mains transformer (without VDE mark) Safety isolating transformer Safety isolating transformer *Mains transformer (without VDE mark) Safety isolating transformer *Mains transformer (without VDE mark) Safety isolating transformer *Mains transformer (without VDE mark) Safety isolating transformer *Mains transformer (without VDE mark) Approvals Approvals cURus, VDE cURus, VDE cURus, VDE cURus, VDE cURus, VDE cURus, VDE Environment Ambient temperature max. 40 °C 40 °C 40 °C 40 °C 40 °C 40 °C Safety and protection Type Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Insulation class VDE=E, UL=class 105 VDE=E, UL=class 105 VDE=E, UL=class 105 VDE=E, UL=class 105 VDE=E, UL=class 105 VDE=E, UL=class 105 Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) II II II II II II Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof Order numbers Order Number see rated output voltage see rated output voltage see rated output voltage see rated output voltage see rated output voltage see rated output voltage Transformers Low profile transformers 1 BLOCK Website 279 Subject to change 1.1 1.2 5.1 1.3 2.1 2.2 3.1 3.2 3.3 5.2 4.0 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |