4 / 11 page ![]() PRELIMINARY TECHNICAL DATA REV. PrF EVAL-ADE7757EB –4– than the frequency on F1 and F2. This output can be used for calibration purposes and is shown connected to a fre- quency counter via the optoisolator in Figure 6. At maximum current (25 A), the power seen by the meter will be 5.5 kW. This will produce a frequency of 0.153 Hz on F1 and F2 when these outputs are calibrated to 100imp/kWhr (100imp/hr = 0.02777 Hz, 0.02777 x 5.5 = 0.153 Hz). From Table V in the ADE7757 datasheet, the closest frequency to 0.153 Hz in the half-scale ac inputs column is for F3, i.e., 0.18 Hz for a nominal internal oscilla- tor frequency of 466k Hz. Therefore F3 is selected by set- ting S1 = 1 and S0 = 0. The choice of CF frequencies in this mode (see Table III in the ADE7757 datasheet) are 32 times F1 and 16 times F1. For this example 32 times F1 is selected by setting SCF = 1. Since the voltage on Channel 1 is fixed, the only possible way of calibrating (adjusting) the output frequency in F1 and F2 is by varying the voltage on Channel 2. This is carried out by varying the attenuation of the line voltage using the trim pot. First we can calculate the voltage required in Channel 2 in order to calibrate the frequency on the logic outputs F1 and F2 to 100imp/kWhr. The ADE7757 datasheet gives the equation which relates the voltage on Channel 1 and Channel 2 to the output frequency on F1 and F2. ref V F V V Freq 2 4 1 2 1 84 515 − × × × = . (1) First a current is selected for calibration, 5 A for example. This gives a Channel 1 voltage of 400 µ Ω x 5 A = 2 mV rms. The on-chip or external reference of 2.5 V is selected using JP10. The output frequency at 5 A on F1 and F2 should be (100imp/kWhr) x 1.1 kW = 0.03055 Hz, where (220 V x 5 A = 1.1 kW). From Equation 1 the voltage on Channel 2 should be set to 54.4 mV. The attenuation network as shown in Figure 1 is used to attenuate 220 V to 54.4 mV. R19 = 590 k Ω, R20 = 200 k Ω, R22 = 100Ω and the trim pot R15 =100Ω. However, since the meter is being calibrated at CF and CF is set to 32 times F1, the voltage on Channel 2 should be adjusted until CF = 32 x 0.03055 Hz = 0.9776 Hz is registered on the frequency counter. The counter should be set up to display the average of ten frequency mea- surements on CF. This will remove any ripple due to the instantaneous power signal. See the ADE7757 datasheet for more details. JUMPER SELECTION The ADE7757 evaluation board comes with several jumper selections that allow the user to exercise all of the ADE7757 functionality. There are also some options such as attenuation networks and optically isolated outputs that allow the ADE7757 to be evaluated under the same conditions as the end application. Table I outlines all the jumper options and explains how they are used. Table I should be used in conjugation with Figure 7, which will make it easier to locate the jumper in question. Table I. Jumper Option Description JP1 Closed Closing this jumper will short resistor R16 and connect analog input V1N directly to SK1B. This has the effect of removing the antialias filter from this input. Open Antialias filter in input V1N is en- abled. JP2 Closed Analog input V1N is connected to analog ground (AGND) via the antialias filter. This jumper should be closed if the Channel 1 is used in a single-ended mode. Open When evaluating the ADE7757, Chan- nel 1 is best used in a differential mode and this jumper should be left open. An example is shown in Figure 3. In this example a shunt is used to sense the current. The shunt can be referenced to the AGND of the board by using TP9 as shown. JP3 Closed Closing this jumper will short resistor R17 and connect analog input V1P directly to SK1C. This has the effect of removing the antialias filter from this input. Open Antialias filter in input V1P is enabled. JP4 Closed Analog input V1P is connected to ana- log ground (AGND) via the antialias filter. Open Normal operation. JP5 Closed Closing this jumper will short resistors R19 and R20. The analog input V2P is connected directly to SK2A. This has the effect of removing the antialias filter/attenuation network from this input. Note: if the board is being con- nected to a high voltage, this jumper must be left open. Open Antialias filter/attenuation network on the input V2P is enabled. JP6 Closed Analog input V2P is connected to ana- log ground (AGND) via the antialias filter/attenuation network. Note: SK2A is also connected to AGND. Be care- ful when connecting this input a high voltage source. Open Normal operation. JP7 Closed Closing this jumper will short resistor R18 and connect analog input V2N directly to SK2B. This has the effect of removing the antialias filter/attenua- tion network from this input. Open Antialias filter/attenuation network in input V2N is enabled. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |