11 / 27 page ![]() ISL81601DEMO2Z 2. Quick Start Guide UG190 Rev.1.00 Page 11 of 27 Oct.16.19 5. Charge complete When the battery is fully charged, IOUT changes to 0 around, VIN is 12V, and IIN is 0 around, which means the test is ready. Figure 12. Input and Output Waves in Charge Mode Figure 13. Fully Charging Information in GUI VIN Battery 5V/Div VOUT System 5V/Div When system voltage is higher than set point, it starts to charge super capacitor in CC mode. When battery voltage is near to set point, it goes to CV mode, and charge current decreases to around 0A. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|