| 数据搜索系统,热门电子元器件搜索 |
|
STLED316S 数据表(PDF) 17 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STLED316S 数据表(HTML) 17 Page - STMicroelectronics |
|
17 / 33 page ![]() STLED316S Key-scan & display cycle 17/33 6 Key-scan & display cycle The display RAM stores the data transmitted from an external device to the STLED316S through the serial interface. Refer to Section 9: Key-scanning and display timing on page 25 for a pictorial representation. The grid and segment outputs are controlled by the display output module. The entire grid will be turned off on channel 1/16 and 16/16 meaning that the first channel and last channel are off. This is referred to as blanking time. During the keyscan time (first cycle from timing generator), the entire grid is turned off and only the segments are enabled one by one (seg0 to seg7). The segment on time is 64 µs. During the LED discrete time (second cycle), the data present on the internal LED buffer is checked. If the data is present, then the brightness setting of each LED in the brightness control register is checked. Then each segment will be enabled or disabled based on the register value. In this duration, the grids 1 to 6 are turned off. The grid corresponding to LED digit is turned on. The LED on duty cycle is 14/16. If the LED/seg1 brightness is 12/16, it means that the segment1 OFF time is 12/16 and on time is 2/16. During 7-segment display time (3rd cycle to 8th cycle), the display status is checked whether it is ON or OFF. If display is ON, then the dimming settings are checked from the configuration register for the grid (it may be common dimming setting or individual dimming setting for each digit). The minimum turn on time is 1/16 and maximum turn on time is 14/16. The blanking time is valid before the turning on and turning off of the grid. The blanking interval is 32 µs. This will continue until the maximum number of digits configured in the register. Once the full cycle is complete, the keyscan cycle will start again. If the display is not turned on, then the timing generation will immediately go to the key scan mode. Initial: All the segments and grids are turned off. During operation: 1. Turn on segment (keyscan) one by one. On time duration is 64 µs. 2. Check the data present in LED register. If data is present, turn on the respective LED grid and segments. 3. Check the display on. If display is turned on, then enable the grid one by one from grid 1 to grid 6 (maximum) and turn on segments. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |