  STLD20CP1 Datasheet HTML 1Page - STMicroelectronics STLD20CP1 Datasheet HTML 2Page - STMicroelectronics STLD20CP1 Datasheet HTML 3Page - STMicroelectronics STLD20CP1 Datasheet HTML 4Page - STMicroelectronics STLD20CP1 Datasheet HTML 5Page - STMicroelectronics STLD20CP1 Datasheet HTML 6Page - STMicroelectronics STLD20CP1 Datasheet HTML 7Page - STMicroelectronics STLD20CP1 Datasheet HTML 8Page - STMicroelectronics STLD20CP1 Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 19 page
background image
Pin description
STLD20CP1
4/19
2
Pin description
Figure 2.
Pin configuration (top view)
Table 2.
Pin description
Symbol
Pin n°
Description
SGND
1
Signal ground
DM1
2
Logic input to control current through the white LEDs, and shutdown mode
function on backlight
DM2
3
Logic input to control current through the white LEDs, and shutdown mode
function on backlight
FB_SU
4
Feedback of step-up. Control current pin on backlight
OUT_SU
5
Sensing of the step-up output voltage in order to provide protection in case of
the output voltage exceeds OVP threshold
IN
6
Supply voltage of the device
SW
7
Switch node. The internal N-channel drain is connected to this pin
PGND
8
Power ground
CN
9
Negative input for the external charge pump capacitor
CP
10
Positive input for the external charge pump capacitor
FB_CP
11
Feedback of charge pump. Control current pin on flash
OUT_CP
12
Out of the charge pump 2X, 1X
TF
13
Logic input to enable charge pump
IT
14
A resistor connected between this pin and IN sets the maximum value of
current in torch mode (SEL=0)
IF
15
A resistor connected between this pin and IN sets the maximum value of
current in flash mode (SEL=1)
SEL
16
Logic input to control flash mode. (see truth table charge pump)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com