8 / 13 page ![]() Application information STCC08 8/13 3 Application information Figure 5. Application example with an MCU direct drive + ACS The placement of a 100 nF capacitor between VCC and GND close to the STCC08 is advised. SW is an electromechanical switch that is part of the application design, for example, the water sensor in a washing machine. 3.1 Recommendations The STCC08 is designed for 5 and 10 mA ACSs, ACSTs and TRIACs. STCC08 basic application The microcontroller reads the AC switch state from the AVF output of the STCC08. The microcontroller can power-off the application driving a front-end relay. Figure 6. Non-insulated application AVF V CC GND R IG AC IN G POWER SWITCH SIGNAL SHAPING AVF DRIVER GATE DRIVER + - MCU 3.3V to 5V V CC V CC AVF GND LOAD LINE NEUTRAL ACS AVF V CC GND R IG AC IN G POWER SWITCH SIGNAL SHAPING AVF DRIVER GATE DRIVER + - MCU 3.3V to 5V V CC V CC AVF GND LOAD NEUTRAL SAFETY TURN OFF ACS LINE FRONT END RELAY |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|