| 数据搜索系统,热门电子元器件搜索 |
|
H8SX/1663 数据表(PDF) 847 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
H8SX/1663 数据表(HTML) 847 Page - Renesas Technology Corp |
|
847 / 1158 page ![]() Section 16 USB Function Module (USB) Rev.1.00 Jun. 07, 2006 Page 795 of 1102 REJ09B0294-0100 16.5.4 Control Transfer Control transfer consists of three stages: setup, data (not always included), and status (figure 16.9). The data stage comprises a number of bus transactions. Operation flowcharts for each stage are shown below. Control-in Setup stage Data stage Status stage Control-out No data SETUP(0) DATA0 SETUP(0) DATA0 SETUP(0) DATA0 IN(1) DATA1 OUT(1) DATA1 IN(0) DATA0 OUT(0) . . . . . . DATA0 IN(0/1) DATA0/1 OUT(0/1) DATA0/1 OUT(1) DATA1 IN(1) DATA1 IN(1) DATA1 Figure 16.9 Transfer Stages in Control Transfer |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |