| 数据搜索系统,热门电子元器件搜索 |
|
SA305 数据表(PDF) 7 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
SA305 数据表(HTML) 7 Page - Cirrus Logic |
|
7 / 8 page ![]() APEX MICROTECHNOLOGY CORPORATION • TELEPHONE (520) 690-8600 • FAX (520) 888-3329 • ORDERS (520) 690-8601 • EMAIL prodlit@apexmicrotech.com 7 GENERAL Please read Apex Application Note 1 “General Operat- ing Considerations” which covers stability, power supplies, heat sinking, mounting, current limit, SOA interpretation, and specification interpretation. Visit www.apexmicrotech.com for design tools that help automate tasks such as calculations for stability, internal power dissipation, current limit, heat sink selection, Apex’s complete Application Notes library, Technical Seminar Workbook and Evaluation Kits. GROUND PINS Analog and Power Grounds should be connected externally at only one point on the motor control board in such a way that there is no current flow through the connection to avoid noise related issues. PROTECTION Each of the six output devices includes short circuit protec- tion to prevent damage from direct shorts to GND or VS. The SA305 is protected against overheating with built in thermal monitoring. The thermal protection will engage when the tem- perature of the MOSFETs reach approximately 160°C. The FAULT output pin will go “HIGH” if either protection circuits engages and will place all MOSFETs in the “OFF” state (high impedance output). The most severe condition for any power device is a direct, hard-wired (“screwdriver”) short from an output to ground. While the short circuit protection will latch the output MOSFETs off the die and package may be required to dissipate a large amount of power until the protection is engaged. This energy can be destructive, particularly at higher operating voltages, so good thermal design is critical if such fault tolerance is required of the system. The SA305 has an internal FAULT latch mechanism by which the device stays disabled (in case a fault occurs) un- less the user resets it. If the SA305 goes into FAULT condition because of short-circuit, over current or high temperature, the DISABLE pin needs to be pulled HIGH (a brief 200ns or more pulse should suffice) to reset the SA305 and resume normal operation. However, before resetting the SA305 the user has to ensure that the FAULT has been eliminated. Please note that under voltage lockout does not set the internal fault latch. CONTROL Each output MOSFET is controlled by a single input. There is a provision inside the SA305 to prevent the upper and lower FET of the same channel from being active at the same time even though the input controls request that both the N and P devices from one half bridge be on. POWER SUPPLY BYPASSING Bypass capacitors to power supply terminals +Vs and –Vs must be connected physically close to the pins to prevent lo- cal parasitic oscillation in the output stage of the SA305. Use electrolytic capacitors at least 10μF per output amp required. Bypass the electrolytic capacitors with high quality ceramic capacitors (X7R) 0.1μF or greater. See the external connec- tions diagram on page 1. CURRENT SENSE The current of each phase can be read using the IMON output pins. The high side of each half bridge current is monitored separately. The current sense output level is as follows: CHANNEL A: I SENSE_A = IO /4148 + 25µA CHANNEL B: I SENSE_B = IO /3491 + 30µA CHANNEL C: I SENSE_C = IO /3819 + 35µA External power current sense resistors are not required with the SA305. However, in order to read the current level using a standard A/D input a resistor of 1KΩ should be shunted across each output. A standard 1/4W resistor is sufficient here. Motor current adjustments are made through the PWM inputs. Above the internal limit the device self-protects. EXTERNAL SCHOTTKY DIODES External schottky diodes are required because of superior reverse recovery characteristics compared to the internal body diodes. SA305 OPERATION The SA305 is used to drive three phase motors but can be used where ever three high current outputs are required. A DSP or microcontroller is used to control and monitor the operation of the SA305. The current through each of the three P channel drive transistors is monitored by on-board circuitry. Current is set using the PWM inputs which drive each FET independently. Once the desired level is reached the inductance of the mo- tor keeps the current near the programmed level. Should the current get to the internally set 12A level, the driver is shutoff to protect itself. Wheneverthereareno“fault”conditionsandtheinputcontrols indicate an output should be on, the P and N drivers will turn on. If the input controls are requiring that P-channel turn on before the N-channel turns off, the SA305 will automatically delay the P-channel turn on. The time between the N turning off and the P turning on or the P channel turning off and the N channel turning on is called dead time. An internally set minimum dead time assures no “shoot through” current and gives the clamp diode time to discharge. OPERATING CONSIDERATIONS SA305 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |