V1.2
HC103M2
HC103M2
HC103M2
Nominal capacitance C0 (at 30°C / 86°F)
160 ± 40 pF
Sensitivity
0.55pF /% RH
Working range humidity
0...100% RH
temperature
-80...120°C (-112...248°F)
Linearity error (0...98% RH)
< ± 2% RH
Hysteresis
1.9 ± 0.25% RH
Response time RH t63
Temperature dependence
1)
dC = -0.0019*RH*(T-30°C) [pF]
Loss tangent
< 0.05
Maximum supply voltage
5V max (UPP)
Maximum DC voltage
< 5mV
Operating frequency
10...100 kHz, recommended 20kHz
Packaging
tray 101.6x101.6 mm (4x4”)
240 sensors
tape and reel
refer to ordering guide
1) more details for t < -20°C on request
T
Tec
echnical Da
hnical Data
ta
Fast High End Humidity Sensors
for Radiosondes / Registering Balloons
Char
Characteristics
acteristics
The average increase of capacitance over the
working range is 55pF. For the range of
0–98% RH linear approximation is possible, errors
will be lower than < ± 2% RH.
The sensor characteristic is determined by the
following linear formula:
C(RH) = C0 * [1+HC0 * RH]
with HC0 = 3420 ± 250 ppm /% RH
relative humidity [% RH]
temperature [°C]
For high accuracy requirements, the sensitivity is determined by the following polynomial:
C(RH) = C0 * [1 + HC0 * RH + K(RH)]
whereby:
K(RH) = A1*RH+A2*RH1.5+A3*RH2+A4*RH2.5
A1 = 2.6657E-3
A2 = -9.6134E-4
A3 = 1.1272E-4
A4 = -4.3E-6