3 / 4 page ![]() D200-54-00 3 I56-710-05 CAUTION Dust covers are an effective way to limit the entry of dust into smoke detector sensing chambers. However, they may not completely prevent airborne dust particles from enter- ing the detector. Therefore, System Sensor recommends the removal of detectors before beginning construction or other dust producing activity. Be sure to remove dust covers from any sensors that were left in place during construction as part of returning the system to service. Testing NOTE: Before testing, notify the proper authorities that the smoke detector system is undergoing mainte- nance and will temporarily be out of service. Dis- able the zone or system undergoing maintenance to prevent unwanted alarms. Detectors must be tested after installation and following periodic maintenance. Test the 2100 as follows: A. Test Switch 1. A recessed test switch is located on the detector hous- ing (See Figure 4). 2. Push and hold the recessed test switch with a 0.1 inch maximum diameter tool such as an allen wrench or small screwdriver. 3. The detector’s LED should light within 5 seconds. OPTIONAL CLASS A WIRING EOL RESISTOR SPECIFIED BY PANEL MANUFACTURER UL LISTED COMPATIBLE CONTROL PANEL INITIATING LOOP + – RA400Z REMOTE ANNUNCIATOR + – RA400Z REMOTE ANNUNCIATOR + – + + + + + + Figure 3. Wiring diagram for the 2100 and 2100T detector: A78-2331-01 B. Test Module (System Sensor Model No. MOD400R). The MOD400R test module can be used with a DMM or analog voltmeter to check the detector sensitivity as de- scribed in the test module’s manual. C. Smoke Entry Test Hold a smoldering punk stick or cotton wick at the side of the detector and gently blow smoke through the de- tector until the unit alarms. D. Direct Heat Method (Model 2100T only – Hair dryer of 1000-1500 watts). Direct the heat toward either of the side thermistors. Hold the heat source about 12 inches from the detector in order to avoid damage to the plastic. The detector will reset only after it has had sufficient time to cool and the power source has been momentarily interrupted. Both smoke and heat detection testing are recommended for verifying system protection capability. A detector that fails to activate with any of the above tests should first be cleaned as outlined in the MAINTENANCE section which follows. If the detector still fails to activate, it should be returned for repair. Notify the proper authorities the system is back on line. PUSH RECESSED SWITCH WITH A 0.1" MAX. DIAMETER TOOL Figure 4. Top and side views showing position of test switch: LED RECESSED TEST SWITCH TEST MODULE SOCKET |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |