| 数据搜索系统,热门电子元器件搜索 |
|
ET70-R 数据表(PDF) 2 Page - Gamewell-FCI by Honeywell |
|
|
|||||||||||||||||||||||||||||
ET70-R 数据表(HTML) 2 Page - Gamewell-FCI by Honeywell |
|
2 / 4 page ![]() ET Low Profile Speakers & Strobes CS-2240 09/01/06 Page 2 of 4 WARNING: CONTACT COOPER-WHEELOCK FOR THE CURRENT “INSTALLATION IN- STRUCTIONS” AND “GENERAL INFORMA- TION” SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PROD- UCTS. THESE MATERIALS CONTAIN IMPOR- TANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL AP- PLIANCES CONNECTED TO SYSTEM SEC- ONDARY POWER SOURCES. • USE RATINGS ON NOTIFICATION APPLI- ANCE CIRCUITS TO HANDLE PEAK CUR- RENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. • COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON’S FIELD OF VIEW. • ADDING, REPLACING OR CHANGING AP- PLIANCES OR CHANGING CANDELA SET- TINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO IN- SURE THAT THE TOTAL AVERAGE CUR- RENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCES OR FUSES. • THE VOLTAGE APPLIED TO THESE PROD- UCTS MUST BE WITHIN THEIR “REGULATED VOLTAGE RANGE”. • INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. • INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLA- TION ISSUES. • USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. • FAILURE TO COMPLY WITH THE INSTALLA- TION INSTRUCTIONS OR GENERAL INFOR- MATION SHEETS COULD RESULT IN IM- PROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PROD- UCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. • CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CON- SIDERATION PRIOR TO DESIGN AND IN- STALLATION OF THESE PRODUCTS, PAR- TICULARLY IN RETROFIT INSTALLATIONS. General Notes • Strobes are designed to flash once per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent min. effective Strobe intensity per UL Standard 1971. • Series ET Speaker Strobes and Series ET Speakers are listed under UL Stan- dard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49° C) and maximum humidity of 85%. • Cooper-Wheelock Weatherproof Appliances are designed to operate over an extended temperature of of -31° F to 150°F (-35°C - 66°C) and all candela rat- ings represent minimum effective strobe intensity based on UL 1638. Maximum humidity of 93% RH + 2% • “Regulated Voltage Range” is the newest terminology used by UL to identify voltage range. Prior to this change, UL used the term, “Listed Voltage Range”. Engineer’s Specifications The speaker appliances shall be Cooper-Wheelock Series ET Speakers and speaker strobe appliances shall be Cooper-Wheelock Series ET Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Signaling Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 8 watts. All models shall have listed sound output of up to 93 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance produces a flash rate of one (1) flash per sec- ond over the Regulated Voltage Range and incorporates a Xenon flashtube en- closed in a rugged Lexan® lens. The strobe is of low current design. If, Multi- Candela Speaker Strobes are specified, the strobe intensity has field selectable settings and is rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95 cd or 115/177cd for ceiling mount. The selector switch for the candela is tamper resistant. The 15/75 strobe is specified when 15 candela UL Standard 1971 listing with 75 candela on-axis is required (ADA compliance). When synchronization is required, the strobe portion of the appliance is compatible with Cooper-Wheelock’s SM, DSM sync modules or power supply with built-in Coo- per-Wheelock Patented Sync Protocol. The strobes do not drift out of synchroniza- tion during operation. If the sync module or Power Supply fails to operate, (i.e.,contacts remain closed), the strobe reverts to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe incorporates a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic fin- ish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series ET speakers and speaker strobes shall be white or red plate. All speakers and speaker strobes shall be backward compatible. Cooper-Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and opera- tionally tested in accordance with their installation instructions at the time of instal- lation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Asso- ciation (NFPA), Underwriters’ Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, prov- ince, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |