| 数据搜索系统,热门电子元器件搜索 |
|
TR-3-R 数据表(PDF) 1 Page - Gamewell-FCI by Honeywell |
|
|
|||||||||||||||||||||||||||||
TR-3-R 数据表(HTML) 1 Page - Gamewell-FCI by Honeywell |
|
1 / 4 page ![]() Flex 405 CS-2405 09/01/06 Page 1 of 4 Description The Gamewell Flex 405 is a 24-volt, five-zone Fire Alarm Control Panel FACP) with built-in communicator and remote-site upload/download capabil- ity. The integral communicator trans- mits event information (alarms, troubles, supervisories, faults, etc.) to a UL-Listed central station. The Flex 405 may be used in a variety of cost- effective applications, including: local fire alarm control panel (communica- tor disabled), fire alarm control panel/ communicator, stand-alone sprinkler supervisory communicator, or slave communicator to a UL-Listed host fire alarm panel (requires normally-open dry contacts to trigger five channels). Selectable transmission formats allow the Flex 405 to communicate to virtually all central stations. Remote-Site Upload/Download The Flex 405 may be downloaded or uploaded without affecting the system fire protection. Download system programming, and upload key system information such as: current system status, history and walk test files; zone, AC line, NAC 1 and NAC 2, resettable power and battery voltages; and system programming. Upload or download within one minute without affecting normal fire panel func- tions. The upload/download function also features multiple security techniques. The Flex 405 requires the PK-CD programming kit, which works with most Hayes- compatible modems (consult factory for listing). Features • Five programmable Initiating Device Circuits (zones). Each zone may be programmed for: two-wire smoke detectors, normally open contact devices (pull stations, heat detectors), four-wire smoke detectors, waterflow operation, supervisory operation, auto-reset supervisory operation. • Two built-in, Class A or B (Style Z or Y) Notification Appliance Circuits (NACs). NACs may be programmed: silenceable, non-silenceable (a strobe circuit can keep flashing after the panel is silenced), auto- silence (program 5 to 30 minutes), silence inhibit (60 seconds), coding (march time, temporal, California). • 3.0 amps of notification appliance power, expandable to 5.0 amps (meets the critical power requirements for ADA and UL-1971 devices). • Two built-in Form-CAlarm andTrouble relays. • Supervisory and communication fail outputs. • Dual-line rotary- or Touch-Tone®-dial DACT interfaces to public telephone network (leased phone lines are not required). • 24-Volt operation. • Built-in voltmeter measures: zone voltage; primary AC line voltage; battery voltage; NAC(s) voltage; resettable 24-volt power. • Surface Mount Technology (SMT). • Fully programmable via built-in keypad (no costly external programmers necessary). • Complies with NFPA 72 (Local, Central Station and Remote Station [DACT only – not polarity reversal] Fire Alarm Systems). • Reporting formats include: 3+1, 4+1, 4+2 Standard + Expanded; 4+1, 4+2, Ademco Express. • Integral battery charger for up to 60 hours of standby power. • Fuseless, power-limited technology meets UL power-limiting requirements. • Programmable alarm presignal timer, alarm verification timer, and optional trouble reminder. • Single-person walk test. Fire drill function. • Zone disable capability (software). • 32-Event history buffer with time-and-date stamp.Accurate real-time clock/calendar. • Extensive built-in transient protection. • Electronics and operational controls fully enclosed in a lockable cabinet capable of housing up to 7 AH batteries. • Optional: contact-by-zone module, remote annunciator, printer interface for on- or off-line printing. Listings Listings and approvals below apply to the basic Flex 405 panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed. • CSFM approved: file 7165-1288:179. • MEA approved: file 366-04-E. Flex 405 Fire Alarm Control Panel with built-in DACT and remote-site upload/download capability |
类似零件编号 - TR-3-R |
|
类似说明 - TR-3-R |
|
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |