| 数据搜索系统,热门电子元器件搜索 |
|
NKA0509SC 数据表(PDF) 2 Page - Murata Manufacturing Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
NKA0509SC 数据表(HTML) 2 Page - Murata Manufacturing Co., Ltd. |
|
2 / 4 page ![]() KDC_NKAC.I02 Page 2 of 4 Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 www.murata-ps.com NKA Series Isolated Sub-Miniature 1W Dual Output DC/DC Converters OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Rated Power1 TA=-40 °C to 120°C 1W Voltage Set Point Accuracy See tolerance envelope Line regulation High VIN to low VIN 1.0 1.2 %/% Load Regulation2 10% load to rated load, 0312 & 0315 8 14 % 10% load to rated load, 3.3V output types 10 15 10% load to rated load, 5V output types 10 12 10% load to rated load, 9V output types 6.5 8 10% load to rated load, 12V output types 6 8.5 10% load to rated load, 15V output types 6 7 Ripple and Noise BW=DC to 20MHz, 0312 & 0315 25 60 mV p-p BW=DC to 20MHz, 3.3V output types 40 80 BW=DC to 20MHz, 5V output types 50 75 BW=DC to 20MHz, 9V output types 40 65 BW=DC to 20MHz, 12V output types 40 60 BW=DC to 20MHz, 15V output types 40 60 ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation test voltage Flash tested for 1 second 3000 VDC Resistance Viso= 1000VDC 10 GΩ GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Switching frequency 0303, 0305, 0312, 0315, 0503 and 0505XE 95 kHz All other types 120 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Specification All output types -40 85 °C Storage -50 130 Case temperature rise above ambient 5V output types 30 All other output types 21 Cooling Free air convection TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NKA series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NKA series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NKA series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. 1. See Derating Graphs. 2. 12V input types have typically 3% less load regulation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |