21 / 32 page ![]() THMC50 REMOTE/LOCAL TEMPERATURE MONITOR AND FAN CONTROLLER WITH SMBus INTERFACE SLIS090 – JULY 1999 21 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PRINCIPLES OF OPERATION diode fault status The THMC50 provides for indications of a fault (open or short-circuited) with the remote thermal diode. Before a remote thermal diode conversion is updated, the status of the remote thermal diode is checked for an open-circuited or short-circuited condition. If such a fault condition occurs, a status bit is set in the status register, and an interrupt is generated (unless masked). An open or shorted condition on the remote diode causes the remote temperature value to read 0x80, does not have an effect on the FAN_SPD output, and does not cause a THERM condition. The following table describes the THMC50 behavior under various remote diode fault conditions: FAULT CONDITION ON Remote_Diode+ and Remote_Diode_ REMOTE TEMPERATURE (REGISTER 0x26) THERM ACTIVATED INT GENERATED REMOTE DIODE DEFAULT STATUS BITS SET Any remote diode pin open 0x80 No† Yes‡ Yes Short between Remote_Diode ± pins 0x80 No† Yes‡ Yes Remote_Diode+ short to supply 0x80 No† Yes‡ Yes Remote_Diode+ short to GND 0x80 No† Yes‡ Yes Remote_Diode– shorted to supply 0x80 No† Yes‡ Yes Remote_Diode– shorted to GND Normal operation No§ No§ No † THERM will not be asserted due to this fault, however, THERM could still activate due to a valid internal temperature THERM condition or if THERM is asserted externally. ‡ INT will not be generated if the Remote diode fault is masked. A remote temperature error INT or a remote temperature error status bit will not be generated by a faulted remote diode. § THERM or INT will be asserted if the temperature in 0x26 meets the criteria for a THERM or INT event and INT is not masked. interrupt output All interrupts are indicated in the interrupt status register and its mirror register. The INT output has an individual mask register and individual masks for each interrupt. This hardware interrupt line can also be enabled/disabled in the configuration register. When enabled, the INT line reflects all interrupt error conditions. INT can be generated from the following sources: D Temperature Interrupt: An interrupt is generated if a high or a low temperature limit has been exceeded on either the local or remote thermal diode. D Remote Diode Fault Interrupt: An interrupt is generated if either a short-circuit or open-circuit fault exists on the remote thermal diode inputs. general-purpose input - GPI The GPI logic input terminal allows the THMC50 SMBus host to read the logic state of this input terminal by reading bit 4 of the interrupt status register (0x41). The logic state of the GPI terminal reported in bit 4 of the interrupt status register (0x41) is inverted from the actual GPI logic state if bit 6 of the configuration register (0x40) is set to a 1. If bit 6 of the configuration register (0x40) is set to a 0, then bit 4 of the interrupt status register (0x41) reports the same logic state present on the GPI terminal. The GPI interrupt bit can be masked by setting bit 4 of the interrupt mask register (0x43) to 1. Note that the state of GPI is not latched into bit 4; this bit simply reflects the state or inverted state of the GPI terminal. If this bit is 1, reading this register does not clear it to 0. interrupt clearing Reading the interrupt status register or the interrupt status register mirror outputs the contents of the register and resets that register only. A subsequent read done before the next conversion is complete indicates a cleared register. Allow at least 1.5 seconds for all registers to be updated between reads. In summary, the interrupt status register clears upon being read, and requires at least 1.5 seconds to be updated. When the interrupt status register clears, the INT output also clears until the registers are updated by the next conversion. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |