| 数据搜索系统,热门电子元器件搜索 |
|
CS2000-OTP 数据表(PDF) 13 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS2000-OTP 数据表(HTML) 13 Page - Cirrus Logic |
|
13 / 30 page ![]() CS2000-OTP DS758F1 13 which the Frequency Synthesizer multiplies while maintaining synchronicity with the frequency reference clock through the Digital PLL. The allowable frequency range for CLK_IN is found in the “AC Electrical Char- acteristics” on page 7. 5.3.1 Adjusting the Minimum Loop Bandwidth for CLK_IN The CS2000 allows the minimum loop bandwidth of the Digital PLL to be adjusted between 1 Hz and 128 Hz using the ClkIn_BW[2:0] global parameter. The minimum loop bandwidth of the Digital PLL direct- ly affects the jitter transfer function; specifically, jitter frequencies below the loop bandwidth corner are passed from the PLL input directly to the PLL output without attenuation. In some applications it is desir- able to have a very low minimum loop bandwidth to reject very low jitter frequencies, commonly referred to as wander. In others it may be preferable to remove only higher frequency jitter, allowing the input wan- der to pass through the PLL without attenuation. Typically, applications in which the PLL_OUT signal creates a new clock domain from which all other sys- tem clocks and associated data are derived will benefit from the maximum jitter and wander rejection of the lowest PLL bandwidth setting. See Figure 11. Systems in which some clocks and data are derived from the PLL_OUT signal while other clocks and data are derived from the CLK_IN signal will often require phase alignment of all the clocks and data in the system. See Figure 12. If there is substantial wander on the CLK_IN signal in these applications, it may be necessary to increase the minimum loop bandwidth allowing this wander to pass through to the CLK_OUT signal in order to maintain phase alignment. For these applications, it is advised to experiment with the loop bandwidth settings and choose the lowest bandwidth setting that does not produce system timing errors due to wandering between the clocks and data synchronous to the CLK_IN domain and those synchronous to the PLL_OUT domain. Figure 11. Low bandwidth and new clock domain LRCK SCLK SDATA MCLK MCLK Wander > 1 Hz Wander and Jitter > 1 Hz Rejected D0 D1 LRCK SCLK SDATA Subclocks generated from new clock domain. or PLL BW = 1 Hz CLK_IN PLL_OUT D0 D1 Jitter Figure 12. High bandwidth with CLK_IN domain re-use D0 D1 LRCK SCLK SDATA MCLK MCLK Wander < 128 Hz Jitter > 128 Hz Rejected Wander < 128 Hz Passed to Output LRCK SCLK SDATA or PLL BW = 128 Hz CLK_IN PLL_OUT Subclocks and data re-used from previous clock domain. Jitter D0 D1 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |