| 数据搜索系统,热门电子元器件搜索 |
|
CS5566 数据表(PDF) 13 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5566 数据表(HTML) 13 Page - Cirrus Logic |
|
13 / 30 page ![]() CS5566 DS806PP2 13 5/4/09 2. OVERVIEW The CS5566 is a 24-bit analog-to-digital converter capable of 5 kSps conversion rate. The device is ca- pable of switching multiple input channels at a high rate with no loss in throughput. The ADC uses a low-latency digital filter architecture. The filter is designed for fast settling and settles to full accuracy in one conversion. The converter is a serial output device. The serial port can be configured to function as either a master or a slave. The converter can operate from an analog supply of 5V or from ±2.5V. The digital interface supports stan- dard logic operating from 1.8, 2.5, or 3.3 V. The CS5566 converts at 5 kSps when operating from a 8 MHz input clock. 3. THEORY OF OPERATION The CS5566 converter provides high-performance measurement of DC or AC signals. The converter can be used to perform single conversions or continuous conversions upon command. Each conversion is in- dependent of previous conversions and can settle to full specified accuracy, even with a full-scale input voltage step. This is due to the converter architecture which uses a combination of a high-speed delta-sig- ma modulator and a low-latency filter architecture. Once power is established to the converter, a reset must be performed. A reset initializes the internal con- verter logic. If CONV is held low then the converter will convert continuously with RDY falling every 1600 MCLKs. This is equivalent to 5 kSps if MCLK = 8.0 MHz. If CONV is tied to RDY, a conversion will occur every 1602 MCLKs. If CONV is operated asynchronously to MCLK, it may take up to 1604 MCLKs from CONV falling to RDY falling. Multiple converters can operate synchronously if they are driven by the same MCLK source and CONV to each converter falls on the same MCLK falling edge. Alternately, CONV can be held low and all devices are reset with RST rising on the same falling edge of MCLK. The output coding of the conversion word is a function of the BP/UP pin. The active-low SLEEP signal causes the device to enter a low-power state. When exiting sleep, the con- verter will take 3083 MCLK cycles before conversions can be performed. RST should remain inactive (high) when SLEEP is asserted (low). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |