| 数据搜索系统,热门电子元器件搜索 |
|
8564EC-103 数据表(PDF) 2 Page - Agilent(Hewlett-Packard) |
|
|
|||||||||||||||||||||||||||||
8564EC-103 数据表(HTML) 2 Page - Agilent(Hewlett-Packard) |
|
2 / 12 page ![]() Frequency Specifications, Agilent 8560 EC Series Unless noted, all specifications describe the instrument’s warranted performance under the following conditions: 5-minute warm-up from ambient conditions, autocoupled controls, digital display, IF ADJ ON, REF LVL CAL adjusted, SECOND IF OUTPUT and 1ST LO OUTPUT terminated in 50 Ω. After a 30-minute warm-up, and over a temperature range of 20 °C to 30 °C, the preselector does not have to be peaked at each signal of interest; under these conditions factory preselector peak values are sufficient to meet all specifications. Typical performance is non-warranted. Supplemental characteristics are denoted by “nominal” and “approximately”; these constitute non-warranted functional performance information derived during the design process and are not tested on a continuing basis. Frequency range 8560EC 8561EC 8562EC 8563EC 8564EC 8565EC Internal 30 Hz 2 to 30 Hz 2 to 30 Hz 2 to 30 Hz 1 to 30 Hz 1 to 30 Hz 1 to mixing 2.9 GHz 6.5 GHz 13.2 GHz 26.5 GHz 40 GHz 50 GHz External 18 GHz to 18 GHz to 18 GHz to 18 GHz to 18 GHz to 18 GHz to mixing 325 GHz 325 GHz 325 GHz 325 GHz 325 GHz 325 GHz Frequency band Harmonic mixing mode (N) 30 Hz to 2.9 GHz 1 2.75 GHz to 6.46 GHz 1 5.86 GHz to 13.2 GHz 2 12.4 GHz to 26.8 GHz 4 26.4 GHz to 31.15 GHz 4 31.0 GHz to 50 GHz 8 Frequency reference Option 856xEC-103 Temperature stability 3 ±1 x 10–8 ±1x10–6 Aging (per year) ±1 x 10–7 ±2x10–6 (per day nom.) ±5 x 10–10 (4) Initial achievable accuracy ±2.2 x 10–8 ±1 x 10–6 Short-term warmup accuracy factors (nominal) 5 minute ±1 x 10–7 15 minute ±1 x 10–8 Frequency readout accuracy (Start, stop, center and marker frequency functions) Span > 2 MHz x N 5 ±(freq readout x freq ref accuracy 6 +5% x span +15% x RBW +10 Hz) Span ≤ 2 MHz x N5 ±(freq readout x freq ref accuracy 6 +1% x span +15% x RBW +10 Hz) Frequency counter accuracy Marker count accuracy ±(marker freq x freq ref accuracy 7 +2 Hz x N 5 (S/N ≥ 25 dB) +1 LSD of counter) Accuracy at 1 GHz ±225 Hz (5-minute warm-up) 7 (25 °C, 1 yr aging, marker resolution = 1 Hz) ±135 Hz (15-minute warm-up) 7 ±3003 Hz (Option 856xEC-103) Delta count accuracy ±(delta freq x freq ref accuracy 6 + 4 Hz x N 5 (S/N ≥ 25 dB) +2 LSD) Counter resolution Selectable from 1 Hz to 1 MHz Frequency span Range 0, 100 Hz to full span (100 Hz x N 5 when using external mixers) Accuracy Span > 2 MHz x N 5 ±5% Span ≤ 2 MHz x N 5 ±1% 2 1. Agilent 8563EC, 8564EC, 8565EC require Option 856xEC-006 for operation below 9 kHz. 2. Agilent 8560EC, 8561EC, 8562EC minimum frequency in AC coupled mode is 100 kHz . In DC coupled mode minimum frequency is 30 Hz. 3. –10 °C to +55 °C, referenced to 25 °C 4. After 7 day warm-up 5. N = harmonic mixing mode number 6. Frequency reference accuracy = aging x time since last adjustment + initial achievable accuracy + temperature stability 7. Short term warmup accuracy factors have been included in this calculation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |